A phase selector based on mathematical morphology for double circuit transmission lines

Z. Lu, W. H. Tang, T. Ji, L. Jiang, Q.H. Wu
{"title":"A phase selector based on mathematical morphology for double circuit transmission lines","authors":"Z. Lu, W. H. Tang, T. Ji, L. Jiang, Q.H. Wu","doi":"10.1109/DRPT.2008.4523799","DOIUrl":null,"url":null,"abstract":"There are problems arising in fault type classification in double circuit transmission lines due to the mutual coupling between the two circuits under fault conditions. A novel fault phase selection scheme is proposed in this paper, which provides an approach to accurately classify the fault types by dealing with six-phase and a model currents using a morphological transformation. The fault characteristics can be effectively extracted from the associating currents by the morphological transformation. The fault phase selection scheme is tested on a simulation model under different fault types, location, resistance and inception angle. All the test results show that the proposed scheme is well suited for classifying fault types in double circuit transmission lines.","PeriodicalId":240420,"journal":{"name":"2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DRPT.2008.4523799","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

There are problems arising in fault type classification in double circuit transmission lines due to the mutual coupling between the two circuits under fault conditions. A novel fault phase selection scheme is proposed in this paper, which provides an approach to accurately classify the fault types by dealing with six-phase and a model currents using a morphological transformation. The fault characteristics can be effectively extracted from the associating currents by the morphological transformation. The fault phase selection scheme is tested on a simulation model under different fault types, location, resistance and inception angle. All the test results show that the proposed scheme is well suited for classifying fault types in double circuit transmission lines.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于数学形态学的双回路传输线选相器
双回传输线在故障状态下,由于两路之间的相互耦合,在故障类型分类方面存在一些问题。本文提出了一种新的故障选相方案,该方案利用形态学变换处理六相和一个模型电流,提供了一种准确分类故障类型的方法。通过形态学变换,可以有效地从关联电流中提取故障特征。在不同故障类型、位置、电阻和起始角的仿真模型上对故障选相方案进行了测试。试验结果表明,该方法适用于双回输电线路的故障类型分类。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Transmission loss allocation using normalized loss weight factors Congestion management based on dynamic zoning and coordinated auctioning method Experimental study on the magnetic-controlled switcher type fault current limiter The simulating research on a improved magnetic shielding type of HTSCFCL Distribution feeder one-line diagrams automatic generation from geographic diagrams based on GIS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1