{"title":"Impedance Source Inverter Wind Turbine and DC Collection System: Fault Ride-Through Analysis","authors":"Muhammad B. M. S. Ramadan, R. T. Naayagi","doi":"10.1109/ICEPE50861.2021.9404490","DOIUrl":null,"url":null,"abstract":"This paper investigates into Fault Ride-Through (FRT) competency during momentary fault interruption of 40 parallel-connected offshore Wind Turbine (WT) unit, in Medium Voltage Direct Current (MVDC) configured transmission system. It proposes to model both aggregative MVDC collection and wind energy conversion systems using Impedance Source Converter (ZSC) in solid-state transformer design and define their corresponding control system architecture. To verify, analytical studies on FRT capabilities against voltage violation events and high inrush current during WTs' start-up were compared with IEEE1547-2018 requirements based on grid-following operation. Simulation studies were conducted in PSCAD environment and have shown positive FRT performances when injected with 100ms fault signals at WT's low-voltage AC line. It proved to efficiently regained stability in a reduced timespan due to aggressive droop control feature rendered by ZSC and endorses positive power quality regulatory despite direct coupling to a weak distribution network: closer to demand loads.","PeriodicalId":250203,"journal":{"name":"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 3rd International Conference on Energy, Power and Environment: Towards Clean Energy Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE50861.2021.9404490","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper investigates into Fault Ride-Through (FRT) competency during momentary fault interruption of 40 parallel-connected offshore Wind Turbine (WT) unit, in Medium Voltage Direct Current (MVDC) configured transmission system. It proposes to model both aggregative MVDC collection and wind energy conversion systems using Impedance Source Converter (ZSC) in solid-state transformer design and define their corresponding control system architecture. To verify, analytical studies on FRT capabilities against voltage violation events and high inrush current during WTs' start-up were compared with IEEE1547-2018 requirements based on grid-following operation. Simulation studies were conducted in PSCAD environment and have shown positive FRT performances when injected with 100ms fault signals at WT's low-voltage AC line. It proved to efficiently regained stability in a reduced timespan due to aggressive droop control feature rendered by ZSC and endorses positive power quality regulatory despite direct coupling to a weak distribution network: closer to demand loads.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
阻抗源逆变器风力发电机和直流采集系统:故障穿越分析
研究了40台并联海上风电机组在中压直流(MVDC)配置输电系统中瞬时故障中断时的故障穿越能力。在固态变压器设计中,采用阻抗源变换器(Impedance Source Converter, ZSC)对MVDC集流和风能转换系统进行建模,并定义相应的控制系统架构。为了验证这一点,将WTs启动过程中FRT抗电压违规事件和高涌流的分析研究与基于电网跟随操作的IEEE1547-2018要求进行了比较。在PSCAD环境下进行了仿真研究,并在WT低压交流线路注入100ms故障信号时显示出积极的FRT性能。事实证明,由于ZSC提供的积极下垂控制特性,它可以在较短的时间内有效地恢复稳定性,并且支持积极的电能质量监管,尽管直接耦合到弱配电网络:更接近需求负载。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Adaptive Kernel Width fourth order Maximum Correntropy based VSC control of grid-tied PV-Battery System MRAS Based Sensorless PMSM Drive With Regenerative Braking For Solar PV-Battery Powered EV Design and FPGA Implementation of an Islanding Detection cum Re-synchronisation Technique for a Grid Connected Inverter in a DC Microgrid Delayed LMS Based Adaptive Control of PV-DSTATCOM System Sliding Mode Observer based Rotor Position Estimation with Field Oriented Control of PMBLDC Motor Drive
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1