Increasing the parameters of electrical distribution networks of town districts with low load density

V. Perepecheny
{"title":"Increasing the parameters of electrical distribution networks of town districts with low load density","authors":"V. Perepecheny","doi":"10.33042/2079-424x-2020-1-57-28-32","DOIUrl":null,"url":null,"abstract":"This article presents the results of research on the parameters of electrical networks with a voltage of 6 (10) and 0.38 kV in relation to capital investments. The analysis of existing methods of estimation of parameters before designing for power supply networks in a small town with low load density is carried out. In modern conditions, in the distribution of electrical networks is of paramount importance the introduction of energy-saving schemes and parameters of power supply systems. One of the main ways to implement them is to increase the efficiency of 6-10 / 0.38 kV networks. In the actual design of electrical networks, economic proportionality can not always be maintained for various reasons: the impact of technical constraints, the discreteness of the rated power of transformers and cable crossing scales, a significant deviation of individual capacities of consumers from the average value. In that case there is an increase in the reduced costs. A methodology for determining the optimal power of transformer substations and optimal\nsections of 0.38 kV power transmission lines is proposed, taking into account the probable nature of the applied load. When assembling the power supply circuit for the optimal form of parameters, voltage, principles of voltage regulation and reactive power compensation. Decisions of this kind are substantiated by technical and economic comparisons of a series of technically acceptable variants of power supply networks. An important measure that facilitates the selection of the most economical option is the assessment of the proposed project, which relates to the selection of the optimal capacity of transformer substation (TS) networks using calculation formulas. The aim of the research was to improve the existing methods on the basis of separate accounting of the reliability coefficient of 0.38 kV and 6-10 kV network. Key words - electric power supply network, network parameters, transformer substation, load density, line wire section, specific load, unit costs, optimum parameter, distribution networks, electric energy.","PeriodicalId":186321,"journal":{"name":"Lighting engineering and power engineering","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lighting engineering and power engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33042/2079-424x-2020-1-57-28-32","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This article presents the results of research on the parameters of electrical networks with a voltage of 6 (10) and 0.38 kV in relation to capital investments. The analysis of existing methods of estimation of parameters before designing for power supply networks in a small town with low load density is carried out. In modern conditions, in the distribution of electrical networks is of paramount importance the introduction of energy-saving schemes and parameters of power supply systems. One of the main ways to implement them is to increase the efficiency of 6-10 / 0.38 kV networks. In the actual design of electrical networks, economic proportionality can not always be maintained for various reasons: the impact of technical constraints, the discreteness of the rated power of transformers and cable crossing scales, a significant deviation of individual capacities of consumers from the average value. In that case there is an increase in the reduced costs. A methodology for determining the optimal power of transformer substations and optimal sections of 0.38 kV power transmission lines is proposed, taking into account the probable nature of the applied load. When assembling the power supply circuit for the optimal form of parameters, voltage, principles of voltage regulation and reactive power compensation. Decisions of this kind are substantiated by technical and economic comparisons of a series of technically acceptable variants of power supply networks. An important measure that facilitates the selection of the most economical option is the assessment of the proposed project, which relates to the selection of the optimal capacity of transformer substation (TS) networks using calculation formulas. The aim of the research was to improve the existing methods on the basis of separate accounting of the reliability coefficient of 0.38 kV and 6-10 kV network. Key words - electric power supply network, network parameters, transformer substation, load density, line wire section, specific load, unit costs, optimum parameter, distribution networks, electric energy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
提高低负荷密度城镇配电网的参数
本文介绍了电压为6(10)和0.38 kV的电网参数与资本投资关系的研究结果。对低负荷密度小城镇供电网络设计前参数估计的现有方法进行了分析。在现代条件下,在配电网中引入节能方案和供电系统参数是至关重要的。实现它们的主要途径之一是提高6-10 / 0.38 kV电网的效率。在电网的实际设计中,由于各种原因,经济比例并不总是能够保持:技术约束的影响,变压器和电缆交叉尺度的额定功率的离散性,消费者个人容量与平均值的显著偏差。在这种情况下,降低的成本会增加。提出了一种确定变电站最优功率和0.38 kV输电线路最优区段的方法,同时考虑了所加负荷的可能性质。在装配时对供电电路进行参数、电压的最佳形式、电压调节原理和无功补偿。这类决定是由一系列技术上可接受的供电网络变体的技术和经济比较所证实的。工程方案的评估是促成最经济方案选择的一项重要措施,它涉及到用计算公式选择变电站网络的最优容量。研究的目的是在单独核算0.38 kV和6-10 kV电网可靠度系数的基础上,对现有方法进行改进。关键词:供电网络,网络参数,变电站,负荷密度,线路线段,比负荷,单位成本,最优参数,配电网,电能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A Refined Mathematical Model of Physical Processes in a Conductor at a High-Current Pulse Discharge To the Problem of Protection of Medium Voltage Instrument Transformers with Fuses: Analytical Research The Evaluation of Electric Power by Separate Analysis of Fourier Transform Components Design and Simulation of a Servo-Drive Motor Using ANSYS Electromagnetics A Decomposition Four-Component Model for Calculating Power Losses in Low-Voltage Power Supply Systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1