O/sub 2/ metabolism in blood vessel walls with stenoses

D. Buerk, S. Dubin, K. Gealow
{"title":"O/sub 2/ metabolism in blood vessel walls with stenoses","authors":"D. Buerk, S. Dubin, K. Gealow","doi":"10.1109/NEBC.1988.19387","DOIUrl":null,"url":null,"abstract":"Vascular tissue O/sub 2/ partial pressure (PO/sub 2/) measurements with recessed cathode O/sub 2/ microelectrodes were made in the walls of isolated rabbit abdominal aortas during saline perfusion in vitro. Three months prior to the experiments, the aortic lumen was reduced by approximately 50% using a tantalum metal clip. A 2- to 3-cm segment of the abdominal aorta including the stenosis was removed and mounted in a chamber maintained at 19.9 kPa. With constant perfusion, the minimum tissue PO/sub 2/ in the wall varied axially along the segment. The minimum wall PO/sub 2/ (+or-SE) was 13.5+or-0.4 kPa at the location 5 mm upstream and 14.2+or-0.8 kPa at the location 5 mm downstream. The lowest value, 11.6+or-0.8 kPa, was found 1 mm downstream. O/sub 2/ disappearance rates (dPO/sub 2//dt) at each location were also measured after stopping perfusion to the segment. The disappearance rates varied axially, with the fastest rate, -4.1+or-0.6 kPa/min, found 1 mm upstream. At 4 and 5 mm upstream and downstream from the stenosis, the rates were essentially the same, at 2.8+or-0.3 kPa/min. The average value for O/sub 2/ metabolism at the upstream and downstream ends is 5.0*10/sup -4/ mL O/sub 2//mL tissue/min.<<ETX>>","PeriodicalId":165980,"journal":{"name":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1988.19387","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Vascular tissue O/sub 2/ partial pressure (PO/sub 2/) measurements with recessed cathode O/sub 2/ microelectrodes were made in the walls of isolated rabbit abdominal aortas during saline perfusion in vitro. Three months prior to the experiments, the aortic lumen was reduced by approximately 50% using a tantalum metal clip. A 2- to 3-cm segment of the abdominal aorta including the stenosis was removed and mounted in a chamber maintained at 19.9 kPa. With constant perfusion, the minimum tissue PO/sub 2/ in the wall varied axially along the segment. The minimum wall PO/sub 2/ (+or-SE) was 13.5+or-0.4 kPa at the location 5 mm upstream and 14.2+or-0.8 kPa at the location 5 mm downstream. The lowest value, 11.6+or-0.8 kPa, was found 1 mm downstream. O/sub 2/ disappearance rates (dPO/sub 2//dt) at each location were also measured after stopping perfusion to the segment. The disappearance rates varied axially, with the fastest rate, -4.1+or-0.6 kPa/min, found 1 mm upstream. At 4 and 5 mm upstream and downstream from the stenosis, the rates were essentially the same, at 2.8+or-0.3 kPa/min. The average value for O/sub 2/ metabolism at the upstream and downstream ends is 5.0*10/sup -4/ mL O/sub 2//mL tissue/min.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
血管狭窄时血管壁的O/sub 2/代谢
在离体兔腹主动脉体外生理盐水灌注过程中,用嵌入式阴极O/sub 2/微电极测量血管组织O/sub 2/分压(PO/sub 2/)。在实验前三个月,使用钽金属夹将主动脉腔缩小了约50%。取下包括狭窄的2- 3cm腹主动脉段,置于维持19.9 kPa的腔室中。在一定灌注条件下,管壁最小组织PO/ sub2 /沿节段轴向变化。上游5mm处的最小PO/sub / (+or-SE)为13.5+或0.4 kPa,下游5mm处的最小PO/sub / (+or-SE)为14.2+或0.8 kPa。最低值为11.6±0.8 kPa,位于下游1mm处。停止灌注至节段后,测量各部位O/sub 2/消失率(dPO/sub 2//dt)。消失速率呈轴向变化,在上游1mm处消失速率最快,为-4.1±0.6 kPa/min。在狭窄上游和下游4和5 mm处,速率基本相同,为2.8+或0.3 kPa/min。上游和下游端O/sub - 2/代谢的平均值为5.0*10/sup -4/ mL O/sub - 2//mL组织/min。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The dielectric properties of canine and normal and neoplastic splenic tissues Aortic compliance indices in the assessment of hypertension Array sensor for arterial pulse recording-reduction of motion artifact A two dimensional fiber optic eye position sensor for tracking and point-of-gaze measurements Assessment of intracranial pressure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1