{"title":"Systemic circulation with high frequency blood flow--analysis from neurophysiological point of view.","authors":"T Yambe,&nbsp;S Nitta,&nbsp;Y Katahira,&nbsp;T Sonobe,&nbsp;S Naganuma,&nbsp;Y Kakinuma,&nbsp;H Akiho,&nbsp;M Tanaka,&nbsp;T Fukuju,&nbsp;M Miura","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The vibrating electromagnetically driven univalved artificial heart, which provided more than 10 1/min at 10 Hz/sec. vibration, was developed in our team. This vibrating electromagnetic pump (VEMP) produced the original flow pattern compared with the flow pattern of the natural heart, so that circulatory regulatory system during maintain the circulation with VEMP must be investigated before the clinical application. In order to assess the effect of high frequency blood flow produced by the VEMP from the neurophysiological point of view, power spectral analysis of the hemodynamics was performed. VEMP was implanted as the total left heart bypass in adult goats and right heart circulation was maintained by natural hearts. In arterial blood pressure during maintain circulation by the high frequency blood flow, Mayer waves (0.01-0.15 Hz) were significantly decreased, though respiratory waves (0.25-0.40 Hz) were not significantly changed. These results suggest that circulatory regulatory system was influenced by the high frequency blood flow produced by the VEMP.</p>","PeriodicalId":76727,"journal":{"name":"The science reports of the research institutes, Tohoku University. Ser. C, Medicine. Tohoku Daigaku","volume":"38 2-4","pages":"69-73"},"PeriodicalIF":0.0000,"publicationDate":"1991-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The science reports of the research institutes, Tohoku University. Ser. C, Medicine. Tohoku Daigaku","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The vibrating electromagnetically driven univalved artificial heart, which provided more than 10 1/min at 10 Hz/sec. vibration, was developed in our team. This vibrating electromagnetic pump (VEMP) produced the original flow pattern compared with the flow pattern of the natural heart, so that circulatory regulatory system during maintain the circulation with VEMP must be investigated before the clinical application. In order to assess the effect of high frequency blood flow produced by the VEMP from the neurophysiological point of view, power spectral analysis of the hemodynamics was performed. VEMP was implanted as the total left heart bypass in adult goats and right heart circulation was maintained by natural hearts. In arterial blood pressure during maintain circulation by the high frequency blood flow, Mayer waves (0.01-0.15 Hz) were significantly decreased, though respiratory waves (0.25-0.40 Hz) were not significantly changed. These results suggest that circulatory regulatory system was influenced by the high frequency blood flow produced by the VEMP.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高频血流的体循环——从神经生理学的角度分析。
电磁驱动的振动式单阀人工心脏,以10hz /sec的速度提供100.1 /min以上的电流。《振动》是我们团队开发的。这种振动电磁泵(VEMP)产生的血流模式与天然心脏的血流模式相比较,因此在临床应用前必须对VEMP维持循环过程中的循环调节系统进行研究。为了从神经生理学的角度评估VEMP产生的高频血流的影响,对血流动力学进行功率谱分析。将VEMP植入成年山羊左心全搭桥,由天然心脏维持右心循环。高频血流维持循环时动脉血压,梅耶波(0.01 ~ 0.15 Hz)明显降低,呼吸波(0.25 ~ 0.40 Hz)无明显变化。这些结果表明,VEMP产生的高频血流影响了循环调节系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Identification of the deterministic chaos in cardiovascular dynamics by the use of the non-linear mathematics. Tumor induction in mice administered neonatally with N-bis(2-hydroxypropyl)nitrosamine (BHPN). Effect of respiratory phases and gravity on mucociliary transport in the normal lungs. Sympathetic nerve activity during maintaining circulation with only left ventricular assist device. Hydrodynamic endurance test of the prosthetic valve used in the various types of the ventricular assist device.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1