Evaluation of lightning performance on transmission system sag

Mohamed Qais, U. Khaled
{"title":"Evaluation of lightning performance on transmission system sag","authors":"Mohamed Qais, U. Khaled","doi":"10.1109/UPEC.2015.7339860","DOIUrl":null,"url":null,"abstract":"A lightning stroke causes current injection into transmission lines at the point of contact. The lightning performance can be difficult to understand without using simulation programs. PSCAD is powerful software was selected to develop the appropriate data required to investigate this phenomena. In this paper, a model of 500 kV transmission line is developed when lightning stroke hits the shield wire directly at the mid-span sag location of transmission line. This study emphasizes on lightning performance when stroke hits either top of transmission tower or position of maximum sag locations between towers. In addition, the effects of lightning strokes on overvoltage along transmission system are studied. The results revealed that the sag of transmission line has a considerable influence on fast transient flashover and induced voltages occurrences across line insulators as well as phase lines.","PeriodicalId":446482,"journal":{"name":"2015 50th International Universities Power Engineering Conference (UPEC)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 50th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC.2015.7339860","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A lightning stroke causes current injection into transmission lines at the point of contact. The lightning performance can be difficult to understand without using simulation programs. PSCAD is powerful software was selected to develop the appropriate data required to investigate this phenomena. In this paper, a model of 500 kV transmission line is developed when lightning stroke hits the shield wire directly at the mid-span sag location of transmission line. This study emphasizes on lightning performance when stroke hits either top of transmission tower or position of maximum sag locations between towers. In addition, the effects of lightning strokes on overvoltage along transmission system are studied. The results revealed that the sag of transmission line has a considerable influence on fast transient flashover and induced voltages occurrences across line insulators as well as phase lines.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
输电系统垂降的防雷性能评价
雷击使电流在接触点注入传输线。如果不使用模拟程序,闪电的性能可能很难理解。PSCAD是一款功能强大的软件,用于开发调查这一现象所需的适当数据。本文建立了500kv输电线路跨中凹陷处雷击直接击中屏蔽线的模型。本研究的重点是当雷击击中输电塔顶或塔间最大凹陷位置时的雷击性能。此外,还研究了雷击对沿线输电系统过电压的影响。结果表明,输电线路的暂垂对线路绝缘子和相线之间的快速暂态闪络和感应电压的产生有很大的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Approximate characterization of large Photovoltaic power plants at the Point of Interconnection Identification of requirements for distribution management systems in the smart grid context A deterioration diagnosis method for Lithium-ion battery based on phase characteristics of internal impedance Congestion pricing in a deregulated market using A.C. Power Transfer Distribution Factors Exploiting massive PMU data analysis for LV distribution network model validation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1