Registration between MVCT reconstructed from EPID and kVCT

Miaomiao Lu, Jun Zhang, Zhibiao Cheng, Junhai Wen
{"title":"Registration between MVCT reconstructed from EPID and kVCT","authors":"Miaomiao Lu, Jun Zhang, Zhibiao Cheng, Junhai Wen","doi":"10.1145/3449388.3449398","DOIUrl":null,"url":null,"abstract":"The registration of two-dimensional MV electronic portal imaging device (EPID) images and digital reconstruction radiograph (DRR) images has been widely used for the setup error correction of radiotherapy, the approaches estimate the 3D transformation is not very accurate. The purpose of this paper is to verify the feasibility of a new setup error estimation method that registers 3D planning CT image and 3D image that is reconstructed based on EPID. EPID images were acquired and used to reconstruct the MVCT by Algebraic Reconstruction Technique (ART) algorithm. The reconstructed image and the planning CT were registered by maximizing the mutual information (MI) between two 3D images. The registration error is less than 3mm, which is suitable for clinical implementation. The study demonstrated that the 3D/3D registration method proposed for the setup error correction of radiotherapy is feasible.","PeriodicalId":326682,"journal":{"name":"2021 6th International Conference on Multimedia and Image Processing","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 6th International Conference on Multimedia and Image Processing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3449388.3449398","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The registration of two-dimensional MV electronic portal imaging device (EPID) images and digital reconstruction radiograph (DRR) images has been widely used for the setup error correction of radiotherapy, the approaches estimate the 3D transformation is not very accurate. The purpose of this paper is to verify the feasibility of a new setup error estimation method that registers 3D planning CT image and 3D image that is reconstructed based on EPID. EPID images were acquired and used to reconstruct the MVCT by Algebraic Reconstruction Technique (ART) algorithm. The reconstructed image and the planning CT were registered by maximizing the mutual information (MI) between two 3D images. The registration error is less than 3mm, which is suitable for clinical implementation. The study demonstrated that the 3D/3D registration method proposed for the setup error correction of radiotherapy is feasible.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
EPID重建的MVCT与kVCT的配准
二维MV电子门静脉成像装置(EPID)图像与数字重建放射成像(DRR)图像的配准一直被广泛用于放疗的设置误差校正,但该方法估计的三维变换精度不高。本文的目的是验证一种新的设置误差估计方法的可行性,该方法将三维规划CT图像与基于EPID重建的三维图像进行配准。获取EPID图像,利用代数重建技术(ART)算法重建MVCT。利用最大互信息(MI)对重建图像和规划CT进行配准。配准误差小于3mm,适合临床实施。研究表明,提出的三维/三维配准方法对放疗的设置误差校正是可行的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Target Classification Algorithms Based on Multispectral Imaging: A Review Vehicle Flow Detection Based on Improved Deep Structure and Deep Sort Research on Behavior Recognition of Dairy Goat Based on Multi-model Fusion Research on UAV Image Mosaic Based on Improved AKAZE Feature and VFC Algorithm Correlation Filters with Pre-position by Reconstruction Error for Visual Tracking
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1