B. Risholt, Elisabeth Gaal Wærnes, B. Time, A. Hestnes
{"title":"Renovation status and technical condition of Norwegian dwellings","authors":"B. Risholt, Elisabeth Gaal Wærnes, B. Time, A. Hestnes","doi":"10.1108/SS-09-2012-0028","DOIUrl":null,"url":null,"abstract":"Purpose – The purpose of this paper is to gain knowledge on the renovation status for Norwegian dwellings that can be used to design attractive energy efficiency measures. Norwegian dwellings are exposed to a windy, cold and moist climate and the technical condition of existing dwellings depend on the owners priorities regarding maintenance and renovation. The paper focuses on the renovation status and technical condition of privately owned detached houses built in Norway in the 1980s constituting 10 per cent of the total Norwegian dwelling stock. These houses are high-energy spenders and are at a stage in their lifetime where major renovation such as new windows and ventilation system is expected. Design/methodology/approach – The status for redecoration, maintenance and renovation as well as the technical condition of 91 dwellings are mapped and analysed. Findings – An analysis of the empirical data identified four categories of houses when considering home upgrades and technical condition: the as built...","PeriodicalId":118605,"journal":{"name":"Structural Survey","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Survey","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/SS-09-2012-0028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
Purpose – The purpose of this paper is to gain knowledge on the renovation status for Norwegian dwellings that can be used to design attractive energy efficiency measures. Norwegian dwellings are exposed to a windy, cold and moist climate and the technical condition of existing dwellings depend on the owners priorities regarding maintenance and renovation. The paper focuses on the renovation status and technical condition of privately owned detached houses built in Norway in the 1980s constituting 10 per cent of the total Norwegian dwelling stock. These houses are high-energy spenders and are at a stage in their lifetime where major renovation such as new windows and ventilation system is expected. Design/methodology/approach – The status for redecoration, maintenance and renovation as well as the technical condition of 91 dwellings are mapped and analysed. Findings – An analysis of the empirical data identified four categories of houses when considering home upgrades and technical condition: the as built...