A. Young, R. Speer, A. Ferriera, G. Mease, A. Pearson, A. Ray
{"title":"On the Performance of Triggered Closing Switches Deployed in High Explosive Pulsed Power Experiments","authors":"A. Young, R. Speer, A. Ferriera, G. Mease, A. Pearson, A. Ray","doi":"10.1109/PPPS34859.2019.9009992","DOIUrl":null,"url":null,"abstract":"Reported in this paper are the results of efforts to improve the performance of a triggered closing switch system used in a 450 kilojoule capacitor bank, which is used as a seed current source for magnetic flux compression generator experiments. The capacitor bank switch utilizes two different high power closing switches: a commercial-off-the-shelf pressurized spark gap and a custom designed solid dielectric puncture switch. Discussion of the spark gap will focus on the results of an investigation aimed at determining the pre-fire rates, self-break voltage distributions, function times and jitter characteristics of two different switches. A campaign aimed at improving the function time and jitter of a Mylar® solid dielectric puncture switch resulted in almost a two-fold decrease in switching characteristics after reducing the thickness of the solid dielectric.","PeriodicalId":103240,"journal":{"name":"2019 IEEE Pulsed Power & Plasma Science (PPPS)","volume":"107 2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Pulsed Power & Plasma Science (PPPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPPS34859.2019.9009992","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Reported in this paper are the results of efforts to improve the performance of a triggered closing switch system used in a 450 kilojoule capacitor bank, which is used as a seed current source for magnetic flux compression generator experiments. The capacitor bank switch utilizes two different high power closing switches: a commercial-off-the-shelf pressurized spark gap and a custom designed solid dielectric puncture switch. Discussion of the spark gap will focus on the results of an investigation aimed at determining the pre-fire rates, self-break voltage distributions, function times and jitter characteristics of two different switches. A campaign aimed at improving the function time and jitter of a Mylar® solid dielectric puncture switch resulted in almost a two-fold decrease in switching characteristics after reducing the thickness of the solid dielectric.