{"title":"Comparison of processing techniques for optimizing the diagnosis of solid insulation based on acoustic emissions from partial discharges","authors":"J. Rubio-Serrano, J. Posada, I. Bua, J. A. García-Souto","doi":"10.1109/ICSD.2013.6619875","DOIUrl":null,"url":null,"abstract":"A partial discharge (PD) is a phenomenon related to the degradation of the insulation systems in HV equipment like power transformers. PD is present in the entire life of the HV equipment but its presence is not an indicative of the existence of a critical defect in the insulation. However, if a set of PD are located in a small region or the repetition rate is high in a small temporal window, then there is a high probability of an imminent failure of the equipment. The detection of the acoustic emission (AE) generated by PD is a non-intrusive technique which can be used for the detection and location of PD in order to perform online condition assessment of insulation systems in power transformers. Although the multiple advantages of the acoustic detection, it has several difficulties to overcome like strong attenuation, signal distortion or accurate arrival time determination. In the last years, new digital signal processing (DSP) techniques has been studied to improve the signal to noise ratio (SNR) of the signals and the detection of the beginning of the detected signals. The objective of this work is the analysis of these DSP techniques in order to improve the diagnosis of power transformers by means of the detection of the AE.","PeriodicalId":437475,"journal":{"name":"2013 IEEE International Conference on Solid Dielectrics (ICSD)","volume":"4 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference on Solid Dielectrics (ICSD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.2013.6619875","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A partial discharge (PD) is a phenomenon related to the degradation of the insulation systems in HV equipment like power transformers. PD is present in the entire life of the HV equipment but its presence is not an indicative of the existence of a critical defect in the insulation. However, if a set of PD are located in a small region or the repetition rate is high in a small temporal window, then there is a high probability of an imminent failure of the equipment. The detection of the acoustic emission (AE) generated by PD is a non-intrusive technique which can be used for the detection and location of PD in order to perform online condition assessment of insulation systems in power transformers. Although the multiple advantages of the acoustic detection, it has several difficulties to overcome like strong attenuation, signal distortion or accurate arrival time determination. In the last years, new digital signal processing (DSP) techniques has been studied to improve the signal to noise ratio (SNR) of the signals and the detection of the beginning of the detected signals. The objective of this work is the analysis of these DSP techniques in order to improve the diagnosis of power transformers by means of the detection of the AE.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于局部放电声发射的固体绝缘诊断优化处理技术的比较
局部放电是电力变压器等高压设备中与绝缘系统劣化有关的一种现象。局部放电存在于高压设备的整个使用寿命中,但它的存在并不表明绝缘存在严重缺陷。但是,如果一组PD位于一个小区域,或者在一个小的时间窗口内重复率很高,那么设备即将发生故障的可能性就很大。局部放电声发射检测是一种非侵入式的检测和定位技术,可用于对电力变压器绝缘系统进行在线状态评估。声波探测虽然具有诸多优点,但也存在着强衰减、信号失真、准确确定到达时间等困难。近年来,人们研究了新的数字信号处理(DSP)技术,以提高信号的信噪比(SNR)和检测信号的起始点。本文的目的是对这些DSP技术进行分析,以便通过声发射的检测来提高电力变压器的诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Contribution to the study of the amorphous phase of polyethylene terephtalate (PET) by the differential scanning calorimerty (DSC) experiments Influence of the thickness and the nature of HVAC insulator model on the flashover voltage and the leakage current Damage processes of polyimide film caused by surface discharge A modified method of suppressing narrow-band interference using FFT power spectrum Depths of chemical impurity states in Polyethylene; The big picture from first principles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1