Impact of embedded wind farms on voltage control and losses of distribution networks

S. Salman, F. Jiang
{"title":"Impact of embedded wind farms on voltage control and losses of distribution networks","authors":"S. Salman, F. Jiang","doi":"10.1109/PTC.1999.826474","DOIUrl":null,"url":null,"abstract":"Voltage magnitude of a distribution system is usually controlled using an on-load tap changer transformer with AVC relay. However, the trend of integrating embedded generation such as wind farms into distribution networks makes it difficult for the AVC relay to maintain voltage magnitude within the statutory limits, particularly if the generator is connected at a long distance from the substation where the relay is located. This paper investigates the use of reactive power injected by a capacitor as a means for assisting the AVC relay for maintaining network voltage magnitude within the required limits. The paper also investigates the effect of the location of such a capacitor on the network voltage profile and network losses.","PeriodicalId":101688,"journal":{"name":"PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PowerTech Budapest 99. Abstract Records. (Cat. No.99EX376)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PTC.1999.826474","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Voltage magnitude of a distribution system is usually controlled using an on-load tap changer transformer with AVC relay. However, the trend of integrating embedded generation such as wind farms into distribution networks makes it difficult for the AVC relay to maintain voltage magnitude within the statutory limits, particularly if the generator is connected at a long distance from the substation where the relay is located. This paper investigates the use of reactive power injected by a capacitor as a means for assisting the AVC relay for maintaining network voltage magnitude within the required limits. The paper also investigates the effect of the location of such a capacitor on the network voltage profile and network losses.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
嵌入式风电场对配电网电压控制和损耗的影响
配电系统的电压幅值通常采用带AVC继电器的有载分接开关变压器进行控制。然而,将嵌入式发电(如风力发电场)集成到配电网络的趋势使得AVC继电器难以将电压幅度保持在法定限制范围内,特别是如果发电机与继电器所在的变电站距离较远。本文研究了利用电容器注入的无功功率作为辅助AVC继电器将网络电压幅度维持在要求范围内的手段。本文还研究了这种电容器的位置对网络电压分布和网络损耗的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The role of the power companies in the fuel cell market A smart security screening approach for large scale power systems Detection of insulator ageing State estimation of electric power system for new technological systems Adaptive equivalenting for calculations of electric power system state
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1