{"title":"Detecting fault during power swing for a series compensated line","authors":"P. K. Nayak, A. Pradhan, P. Bajpai","doi":"10.1109/ICEAS.2011.6147076","DOIUrl":null,"url":null,"abstract":"The apparent impedance seen by a distance relay may fall within its operating zone during power swing. This may cause the relay to trip unnecessarily. To avoid unintended trip operation during such conditions, a power swing blocking function is utilized in distance relays. However, if a fault occurs during power swing, the relay should detect the fault and trip as soon as possible for maintaining security. Detection of fault during power swing in a series compensated line is more complicated due to the presence of protection circuit of the capacitor. This paper proposes a negative sequence current based technique for detecting fault during power swing in a series compensated line. The technique is tested for symmetrical and unsymmetrical faults in a system simulated through EMTDC/PSCAD. The method is compared with available techniques.","PeriodicalId":273164,"journal":{"name":"2011 International Conference on Energy, Automation and Signal","volume":"44 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Energy, Automation and Signal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEAS.2011.6147076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18
Abstract
The apparent impedance seen by a distance relay may fall within its operating zone during power swing. This may cause the relay to trip unnecessarily. To avoid unintended trip operation during such conditions, a power swing blocking function is utilized in distance relays. However, if a fault occurs during power swing, the relay should detect the fault and trip as soon as possible for maintaining security. Detection of fault during power swing in a series compensated line is more complicated due to the presence of protection circuit of the capacitor. This paper proposes a negative sequence current based technique for detecting fault during power swing in a series compensated line. The technique is tested for symmetrical and unsymmetrical faults in a system simulated through EMTDC/PSCAD. The method is compared with available techniques.