Outflow Obstruction of Soft-Shell Venous Reservoir Bags: A Preliminary Investigation

D. Palanzo, R. M. Montesano, Joseph M Castagna
{"title":"Outflow Obstruction of Soft-Shell Venous Reservoir Bags: A Preliminary Investigation","authors":"D. Palanzo, R. M. Montesano, Joseph M Castagna","doi":"10.1051/ject/2000322066","DOIUrl":null,"url":null,"abstract":"Potential problems have occurred during cardiopulmonary bypass where the area directly above the outlet port of the soft-shell venous reservoir containing a screen has collapsed similar to when the bag is empty, although there are still several hundred milliliters in the bag. A preliminary investigation was conducted to rule out the possibility of this outflow obstruction being attributable to poor flow design through the reservoirs. The test circuit consisted of a cardiotomy reservoir, a centrifugal pump, 3/8 and 1/2 in PVC tubing, and one of the test venous reservoirs (BARD S-2116, Medtronic 1385 and MVR-1600, Sarns 4858). The circuit was primed with outdated packed red blood cells, platelets, human albumin, normal saline, and 10,000 units of sodium heparin in concentrations to simulate routine bypass. Each reservoir was tested at 6.5–7.0 L/min flows for a least 20 min each.\nNone of the reservoirs tested demonstrated the phenomenon that had been observed clinically. This dismisses flow design flaws as a possible cause. Further clinical investigation must be performed to identify the possible cause or causes of this problem.","PeriodicalId":309024,"journal":{"name":"The Journal of ExtraCorporeal Technology","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of ExtraCorporeal Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ject/2000322066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Potential problems have occurred during cardiopulmonary bypass where the area directly above the outlet port of the soft-shell venous reservoir containing a screen has collapsed similar to when the bag is empty, although there are still several hundred milliliters in the bag. A preliminary investigation was conducted to rule out the possibility of this outflow obstruction being attributable to poor flow design through the reservoirs. The test circuit consisted of a cardiotomy reservoir, a centrifugal pump, 3/8 and 1/2 in PVC tubing, and one of the test venous reservoirs (BARD S-2116, Medtronic 1385 and MVR-1600, Sarns 4858). The circuit was primed with outdated packed red blood cells, platelets, human albumin, normal saline, and 10,000 units of sodium heparin in concentrations to simulate routine bypass. Each reservoir was tested at 6.5–7.0 L/min flows for a least 20 min each. None of the reservoirs tested demonstrated the phenomenon that had been observed clinically. This dismisses flow design flaws as a possible cause. Further clinical investigation must be performed to identify the possible cause or causes of this problem.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
软壳静脉储液袋流出梗阻的初步研究
在体外循环过程中,可能出现的问题是,含有屏幕的软壳静脉储液器出口正上方的区域塌陷,类似于空袋时的情况,尽管袋中仍有几百毫升。进行了初步调查,以排除这种流出障碍是由于通过水库的水流设计不佳造成的可能性。测试回路包括一个开心术储液器、一个离心泵、3/8和1/2 PVC管,以及一个测试静脉储液器(BARD S-2116, Medtronic 1385和MVR-1600, Sarns 4858)。电路中填充了过时的红细胞、血小板、人白蛋白、生理盐水和10,000单位的肝素钠,以模拟常规旁路。每个储层以6.5-7.0 L/min的流速进行测试,每次至少20分钟。所测储层均未表现出临床观察到的现象。这就排除了流设计缺陷作为可能原因的可能性。进一步的临床调查必须进行,以确定可能的原因或原因,这一问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Standardized Therapies after ECMO Program (STEP); A Novel Approach to Pediatric post-ECMO Care Traditional vs. modified Ringer lactate-based del Nido cardioplegia impacts on clinical outcomes in patients undergoing coronary artery bypass grafting: results from a clinical trial Comparison of routine del Nido cardioplegia vs two types of modified del Nido cardioplegias for myocardial protection among patients undergoing coronary artery bypass grafting (CABG) surgeries: a randomized double-blind clinical trial. Adapting and Applying Student-centered Learning in a Perfusion Clinical Rotation Adapting and Applying Student-centered Learning in a Perfusion Clinical Rotation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1