{"title":"Liquid chromatographic determination of tolnaftate in commercial products.","authors":"R D Thompson, M Carlson","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A liquid chromatographic (LC) method for the determination of the antifungal agent tolnaftate was developed. Isolation of the analyte was achieved by direct extraction or dilution with acetonitrile-water (80 + 20) followed by reverse-phase liquid chromatography using a C18 column. The mobile phase was acetonitrile-water (80 + 20) acidified with phosphoric acid. Detection was by UV absorption at a wavelength of 257 nm. The proposed procedure was applied to 20 consumer products comprising 6 formulation types, including solutions, powders, liquid and power aerosols, creams, and gels. The precision (RSD) for the products ranged from 0.23 to 1.16% (n = 5), and recoveries via fortification ranged from 98.1 to 103.0%. Six different brands of C18 columns were evaluated for use with the method. The overall simplicity and versatility of the method suggest possible adaptations to both regulatory and quality-control situations.</p>","PeriodicalId":14752,"journal":{"name":"Journal - Association of Official Analytical Chemists","volume":"74 4","pages":"603-7"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal - Association of Official Analytical Chemists","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A liquid chromatographic (LC) method for the determination of the antifungal agent tolnaftate was developed. Isolation of the analyte was achieved by direct extraction or dilution with acetonitrile-water (80 + 20) followed by reverse-phase liquid chromatography using a C18 column. The mobile phase was acetonitrile-water (80 + 20) acidified with phosphoric acid. Detection was by UV absorption at a wavelength of 257 nm. The proposed procedure was applied to 20 consumer products comprising 6 formulation types, including solutions, powders, liquid and power aerosols, creams, and gels. The precision (RSD) for the products ranged from 0.23 to 1.16% (n = 5), and recoveries via fortification ranged from 98.1 to 103.0%. Six different brands of C18 columns were evaluated for use with the method. The overall simplicity and versatility of the method suggest possible adaptations to both regulatory and quality-control situations.