Preliminary evaluation of sensititre system for identifying gram-negative bacilli.

Microbiologica Pub Date : 1991-07-01
G Mucignat, G L Tarabini-Castellani, L Pascoli, W De Cal, G Bruschetta, P De Paoli, G Santini
{"title":"Preliminary evaluation of sensititre system for identifying gram-negative bacilli.","authors":"G Mucignat,&nbsp;G L Tarabini-Castellani,&nbsp;L Pascoli,&nbsp;W De Cal,&nbsp;G Bruschetta,&nbsp;P De Paoli,&nbsp;G Santini","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The automated microdilution Sensititre System (Sensititre, LtD.) was evaluated for the identification of 120 clinically isolated fermenter and non-fermenter Gram negative bacilli and of 12 ATCC reference strains (American Type Culture Collection). Daily and overnight (5 and 18 hours) identifications were performed according to the manufacturer. In both cases, the results were compared with those obtained with the overnight API 20E (API System, La Balme les Grottes, Montalieu Vercieu) used as reference method. Concordance between the results obtained after 5 hrs of incubation and those obtained with API 20E was found in 65% of cases (acceptable identification criteria with probability over 80%). When results were determined after 18 hrs of incubation (identification criteria with probably over 80%) concordance was found in 82.5%. Reproducibility obtained by repeated (10 times) identification with four different strains was 100% both at 5 hrs and 18 hrs. Identification accuracy of the 12 ATCC strains was 8/12 (66.6%) after 5 hrs and 12/12 (100%) after 18 hrs.</p>","PeriodicalId":77264,"journal":{"name":"Microbiologica","volume":"14 3","pages":"261-5"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microbiologica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The automated microdilution Sensititre System (Sensititre, LtD.) was evaluated for the identification of 120 clinically isolated fermenter and non-fermenter Gram negative bacilli and of 12 ATCC reference strains (American Type Culture Collection). Daily and overnight (5 and 18 hours) identifications were performed according to the manufacturer. In both cases, the results were compared with those obtained with the overnight API 20E (API System, La Balme les Grottes, Montalieu Vercieu) used as reference method. Concordance between the results obtained after 5 hrs of incubation and those obtained with API 20E was found in 65% of cases (acceptable identification criteria with probability over 80%). When results were determined after 18 hrs of incubation (identification criteria with probably over 80%) concordance was found in 82.5%. Reproducibility obtained by repeated (10 times) identification with four different strains was 100% both at 5 hrs and 18 hrs. Identification accuracy of the 12 ATCC strains was 8/12 (66.6%) after 5 hrs and 12/12 (100%) after 18 hrs.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
革兰氏阴性杆菌敏感系统的初步评价。
采用自动微稀释敏敏系统(Sensititre, LtD.)鉴定120株临床分离的发酵和非发酵革兰氏阴性杆菌和12株ATCC参考菌株(American Type Culture Collection)。根据制造商进行每日和夜间(5和18小时)鉴定。在这两种情况下,将结果与隔夜API 20E (API System, La Balme les Grottes, Montalieu Vercieu)作为参考方法获得的结果进行比较。65%的病例在孵育5小时后获得的结果与API 20E获得的结果一致(可接受的识别标准,概率超过80%)。孵育18小时后确定结果(鉴定标准可能超过80%),82.5%的人发现一致性。4种不同菌株在5 h和18 h的重复性均为100%。5 h后对12株ATCC的鉴定准确率为8/12 (66.6%),18 h后为12/12(100%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Methisoprinol-effect on the replication cycle of human hepatitis A virus. Absence of HTLV-I/II infection in blood donors with positive and inconclusive HTLV-I/II serology. Role of phospholipids in BK virus infection and haemagglutination. The response of pregnant gilts previously given an inactivated preparation of porcine parvovirus (PPV) to challenge infection with a fully virulent PPV. A mechanism involved in the plaque enhancement effect of sodium thiosulfate for foot-and-mouth disease viruses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1