Ruifeng Xu, Li-xin Ma, Bo Hu, He-ran Ma, Bo-hao Tao
{"title":"Intelligent High-Voltage Discharge Fault Detection and Its Diagnosis Methods Based on ANN","authors":"Ruifeng Xu, Li-xin Ma, Bo Hu, He-ran Ma, Bo-hao Tao","doi":"10.1109/IPTC.2011.37","DOIUrl":null,"url":null,"abstract":"In order to prevent the harm of corona, the power sector needs to detect and analyze the fault of corona discharge. This paper put forward a single-channel structure corona detection system based on solar-blind UV detection technology, which is able to locate corona discharge effectively. And the absolute discharge area formula has been derived to quantify the corona discharge intensity. On that basis, a corona discharge fault diagnosis method has been built based on BP neural network, which can make the correct classification of the corona failure.","PeriodicalId":388589,"journal":{"name":"2011 2nd International Symposium on Intelligence Information Processing and Trusted Computing","volume":"79 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 2nd International Symposium on Intelligence Information Processing and Trusted Computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPTC.2011.37","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
In order to prevent the harm of corona, the power sector needs to detect and analyze the fault of corona discharge. This paper put forward a single-channel structure corona detection system based on solar-blind UV detection technology, which is able to locate corona discharge effectively. And the absolute discharge area formula has been derived to quantify the corona discharge intensity. On that basis, a corona discharge fault diagnosis method has been built based on BP neural network, which can make the correct classification of the corona failure.