Frame-angle-based controller for 3φ interconnected PV systems

S. Saleh
{"title":"Frame-angle-based controller for 3φ interconnected PV systems","authors":"S. Saleh","doi":"10.1109/ICPS.2018.8370006","DOIUrl":null,"url":null,"abstract":"This paper presents the development and performance of a controller for photovoltaic (PV) systems that are grid-connected through a 3φ wavelet modulated (WM) dc-ac power electronic converter (PEC). The proposed controller is designed using decoupled current control loops, which have the d — q-axis components of the currents injected to the grid, as their inputs. The outputs of this controller are command values for the d — q-axis components of the voltages produced by a 3φ WM dc-ac PEC (v∗<inf>Id</inf> and v<sup>∗</sup><inf>Iq</inf>). The values of v∗<inf>Id</inf> and v∗<inf>Iq</inf> are used to determine the required angle ê, which aligns the frame spanned by the actual d-q-axis components of the voltages produced by the controlled 3φ WM dc-ac PEC (v<inf>Id</inf> and v<inf>Iq</inf>). The adjustments of ê allow changing the phase angles of the sinusoidal reference signals used to generate the wavelet modulation switching pulses. The proposed controller is implemented for performance testing using a 15 kW ac module PV system that is interconnected through a 3φ, 6-pulse, WM dc-ac PEC. The performance of the frame-angle controller is tested for different changes in the power delivered to the grid and system parameters. Test results demonstrate stable, fast, and accurate control actions that are complimented by negligible sensitivity to levels of power delivery to the grid, as well as variations in system parameters.","PeriodicalId":142445,"journal":{"name":"2018 IEEE/IAS 54th Industrial and Commercial Power Systems Technical Conference (I&CPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE/IAS 54th Industrial and Commercial Power Systems Technical Conference (I&CPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.2018.8370006","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents the development and performance of a controller for photovoltaic (PV) systems that are grid-connected through a 3φ wavelet modulated (WM) dc-ac power electronic converter (PEC). The proposed controller is designed using decoupled current control loops, which have the d — q-axis components of the currents injected to the grid, as their inputs. The outputs of this controller are command values for the d — q-axis components of the voltages produced by a 3φ WM dc-ac PEC (v∗Id and vIq). The values of v∗Id and v∗Iq are used to determine the required angle ê, which aligns the frame spanned by the actual d-q-axis components of the voltages produced by the controlled 3φ WM dc-ac PEC (vId and vIq). The adjustments of ê allow changing the phase angles of the sinusoidal reference signals used to generate the wavelet modulation switching pulses. The proposed controller is implemented for performance testing using a 15 kW ac module PV system that is interconnected through a 3φ, 6-pulse, WM dc-ac PEC. The performance of the frame-angle controller is tested for different changes in the power delivered to the grid and system parameters. Test results demonstrate stable, fast, and accurate control actions that are complimented by negligible sensitivity to levels of power delivery to the grid, as well as variations in system parameters.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于框架角度的3φ互联光伏系统控制器
本文介绍了一种3φ小波调制(WM)直流-交流电力电子变换器(PEC)并网光伏系统控制器的研制及其性能。所提出的控制器采用解耦电流控制回路设计,该回路将电流的d - q轴分量注入电网,作为其输入。该控制器的输出是由3φ WM直流-交流PEC (v∗Id和v∗Iq)产生的电压的d - q轴分量的命令值。v∗Id和v∗Iq的值用于确定所需的角度ê,它对齐由控制的3φ WM直流-交流PEC (vId和vIq)产生的电压的实际d-q轴分量所跨越的框架。ê的调整允许改变用于产生小波调制开关脉冲的正弦参考信号的相位角。所提出的控制器用于使用15 kW交流模块光伏系统进行性能测试,该系统通过3φ, 6脉冲,WM直流-交流PEC互连。在不同的电网输出功率和系统参数变化条件下,对框架角控制器的性能进行了测试。测试结果显示了稳定、快速和准确的控制动作,并且对电网供电水平以及系统参数变化的灵敏度可以忽略不计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluating the impact of wind power probabilistic forecasting on very-short-term generation scheduling for Wind-Storage Combined Generation System Emission-aware stochastic resource planning scheme for data center microgrid considering batch workload scheduling and risk management High-resistance grounding protection scheme of 11 kV generating plant Interconnections criteria of grounding grids in global grounding systems AC microgrid grounding strategies
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1