Research on fault ride-through capacity enhancement of FSWT using fault current limiters of different types and impedance

Jiaxin Yuan, Y. Lei, Baichao Chen
{"title":"Research on fault ride-through capacity enhancement of FSWT using fault current limiters of different types and impedance","authors":"Jiaxin Yuan, Y. Lei, Baichao Chen","doi":"10.1109/PESGM.2015.7285926","DOIUrl":null,"url":null,"abstract":"This paper analyzed the method of using FCL to enhance FRT capacity of FSWT and compared the performance of resistive-type fault current limiters (RFCL) and reactor-type fault current limiters (LFCL) of different limiting impedance. The minimum required value of the impedance for maintaining stable operation of FSWT during fault is determined, as well as dynamic stable speed and critical clearing time (CCT). The method has been validated by transient studies in a simple system by PSCAD/EMTDC. Simulation results demonstrate that the enhancement of FRT is related highly with the limiting impedance of FCL. The RFCL has the advantage of choosing limiting impedance and transient oscillate, while the LFCL with minimum required impedance has a better performance on the enhancement of FRT.","PeriodicalId":423639,"journal":{"name":"2015 IEEE Power & Energy Society General Meeting","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Power & Energy Society General Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESGM.2015.7285926","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

This paper analyzed the method of using FCL to enhance FRT capacity of FSWT and compared the performance of resistive-type fault current limiters (RFCL) and reactor-type fault current limiters (LFCL) of different limiting impedance. The minimum required value of the impedance for maintaining stable operation of FSWT during fault is determined, as well as dynamic stable speed and critical clearing time (CCT). The method has been validated by transient studies in a simple system by PSCAD/EMTDC. Simulation results demonstrate that the enhancement of FRT is related highly with the limiting impedance of FCL. The RFCL has the advantage of choosing limiting impedance and transient oscillate, while the LFCL with minimum required impedance has a better performance on the enhancement of FRT.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用不同类型和阻抗的故障限流器增强FSWT故障穿越能力的研究
本文分析了利用FCL提高FSWT FRT容量的方法,并比较了不同限制阻抗的电阻式故障限流器(RFCL)和电抗式故障限流器(LFCL)的性能。确定了故障时维持FSWT稳定运行所需的最小阻抗值,以及动态稳定速度和临界清除时间(CCT)。该方法已通过PSCAD/EMTDC在一个简单系统中的瞬态研究得到验证。仿真结果表明,FCL的极限阻抗与FRT的增强密切相关。RFCL具有选择极限阻抗和瞬态振荡的优点,而要求阻抗最小的LFCL在增强FRT方面具有更好的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Information theoretic index for regime shifts in power systems Optimal voltage regulation for unbalanced distribution networks considering distributed energy resources Evaluation of NERC's BRD frequency control standard in hydroelectric generation Distributed multi-agent scheme to improve dynamic voltage stability of distribution networks A multiagent system for residential DC microgrids
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1