Development of a single phase prepaid Electrical Energy Meter using 89S8252 microcontroller architecture

G. Mostafa
{"title":"Development of a single phase prepaid Electrical Energy Meter using 89S8252 microcontroller architecture","authors":"G. Mostafa","doi":"10.1109/ICAEE.2015.7506858","DOIUrl":null,"url":null,"abstract":"The Electricity Company implements the `Prepaid Electrical Energy Meter (PEM)' scheme among the electricity consumers to meet the objectives of: (i) collecting advance money and (ii) motivating the customers to make conservative use of electricity. The 2nd objective can be effectively achieved with an indoor type PEM fitted with 7-segment bright display unit. The meter designer aims, using appropriate hardware modules and software routines, to guide the PEM for cycling through the following steps: (i) deduct cost of every 0.01kwhr energy consumed, (ii) display balance, (iii) check balance, (iv) disconnect load at zero balance, (v) issue alarm signal to engage correct prepaid card, (vi) read the prepaid card, (vii) zeroing the prepaid card, (viii) update balance, (ix) save balance in nonvolatile EEPROM at power failure, and (x) retrieve balance from EEPROM at power resumption. This paper has described, based on extensive experiments on real hardware using AT89S8252-ADE7755-AT90S2313 chip set, the implementation methodology of a PEM with bright display unit. A prototype meter has been built, tested and found to work as per standard specifications.","PeriodicalId":123939,"journal":{"name":"2015 International Conference on Advances in Electrical Engineering (ICAEE)","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Advances in Electrical Engineering (ICAEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAEE.2015.7506858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The Electricity Company implements the `Prepaid Electrical Energy Meter (PEM)' scheme among the electricity consumers to meet the objectives of: (i) collecting advance money and (ii) motivating the customers to make conservative use of electricity. The 2nd objective can be effectively achieved with an indoor type PEM fitted with 7-segment bright display unit. The meter designer aims, using appropriate hardware modules and software routines, to guide the PEM for cycling through the following steps: (i) deduct cost of every 0.01kwhr energy consumed, (ii) display balance, (iii) check balance, (iv) disconnect load at zero balance, (v) issue alarm signal to engage correct prepaid card, (vi) read the prepaid card, (vii) zeroing the prepaid card, (viii) update balance, (ix) save balance in nonvolatile EEPROM at power failure, and (x) retrieve balance from EEPROM at power resumption. This paper has described, based on extensive experiments on real hardware using AT89S8252-ADE7755-AT90S2313 chip set, the implementation methodology of a PEM with bright display unit. A prototype meter has been built, tested and found to work as per standard specifications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于89S8252单片机架构的单相预付费电能表的研制
电力公司在电力用户中推行“预付电能表”计划,以达致以下目标:(i)收取预付款项及(ii)鼓励用户节约用电。第二个目标可以通过配备7段明亮显示单元的室内型PEM有效实现。仪表设计人员的目的是,使用适当的硬件模块和软件例程,通过以下步骤指导PEM循环:(i)扣除每消耗0.01千瓦时电能的费用,(ii)显示余额,(iii)检查余额,(iv)在零余额时断开负载,(v)发出报警信号以使用正确的预付卡,(vi)读取预付卡,(vii)将预付卡调零,(viii)更新余额,(ix)在电源故障时将余额保存在非易失性EEPROM中,(x)在电源恢复时从EEPROM中检索余额。本文采用AT89S8252-ADE7755-AT90S2313芯片组在实际硬件上进行了大量的实验,描述了带亮显示单元的PEM的实现方法。一个原型仪表已经建成,测试,并发现按标准规范工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Problem analysis and probable solution of existing interconnected grid system of Chittagong region Development of an LCL filter for a residential Microgrid system Hardware implementation of grid connected transformer-less semi-Z-source inverter topology to mitigate common mode leakage current and THD Earthquake monitoring and warning system The next generation of irrigation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1