Design and Development of an Open-Source Adl-Compliant Prosthetic Arm for Trans-Radial Amputees

L. Timm, Maureen Etuket, S. Sivarasu
{"title":"Design and Development of an Open-Source Adl-Compliant Prosthetic Arm for Trans-Radial Amputees","authors":"L. Timm, Maureen Etuket, S. Sivarasu","doi":"10.1115/dmd2022-1029","DOIUrl":null,"url":null,"abstract":"\n Presently, open source prosthesis are not optimized to assist the dominant hand in performing bimanual ADL. This research study was thus geared towards the design and experimental validation of an open-source below-elbow prosthetic arm, called the ADL arm, that is functionally optimized for the performance of ADL in the unilateral TR amputee population.\n The ADL arm is 3D printed; the design validation involved functional assessment - using the AHAP and simulated use assessment with healthy volunteer participants after obtaining Ethics approval. In accordance with AHAP; the ADL arm presented with an overall GAS of 68% and a partial GAS of >75 % for 4/5 ADL grasps. Usability Assessment involved the performance of ADL tasks coupled with the completion of the SUS. The perceived usability of the device was found to increase with increased device familiarity, yielding an overall score of 84.29.\n Through the tests conducted, the ADL arm was found to be functionally competent, relatively acceptable with proven ability to assist in the performance of ADLs in a simulated-use environment. A number of design modifications and clinical tests are however recommended to overcome the limitations of the current design and corroborate the results obtained in this study.","PeriodicalId":236105,"journal":{"name":"2022 Design of Medical Devices Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 Design of Medical Devices Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/dmd2022-1029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Presently, open source prosthesis are not optimized to assist the dominant hand in performing bimanual ADL. This research study was thus geared towards the design and experimental validation of an open-source below-elbow prosthetic arm, called the ADL arm, that is functionally optimized for the performance of ADL in the unilateral TR amputee population. The ADL arm is 3D printed; the design validation involved functional assessment - using the AHAP and simulated use assessment with healthy volunteer participants after obtaining Ethics approval. In accordance with AHAP; the ADL arm presented with an overall GAS of 68% and a partial GAS of >75 % for 4/5 ADL grasps. Usability Assessment involved the performance of ADL tasks coupled with the completion of the SUS. The perceived usability of the device was found to increase with increased device familiarity, yielding an overall score of 84.29. Through the tests conducted, the ADL arm was found to be functionally competent, relatively acceptable with proven ability to assist in the performance of ADLs in a simulated-use environment. A number of design modifications and clinical tests are however recommended to overcome the limitations of the current design and corroborate the results obtained in this study.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
面向桡骨截肢者的开源adl兼容义肢的设计与开发
目前,开源假体在辅助优势手进行双手ADL方面还没有得到优化。因此,本研究旨在设计和实验验证一种名为ADL臂的开源肘部以下假肢,该假肢在功能上针对单侧TR截肢者的ADL性能进行了优化。ADL手臂是3D打印的;设计验证包括使用AHAP进行功能评估,并在获得伦理批准后对健康志愿者进行模拟使用评估。按照AHAP;ADL手臂在4/5次ADL抓取时,总体GAS为68%,部分GAS > 75%。可用性评估包括ADL任务的性能以及SUS的完成情况。该设备的感知可用性被发现随着设备熟悉度的增加而增加,总体得分为84.29。通过进行的测试,发现ADL臂在功能上是合格的,相对可接受的,在模拟使用环境中有能力协助ADL的性能。然而,建议进行一些设计修改和临床试验,以克服当前设计的局限性,并证实本研究中获得的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Communicating Cybersecurity and Privacy Design Attributes through Privacy Labeling of Consumer Electronic Medical Devices A Novel Tool for Auricle Retraction During Closure of Post-Auricular Incisions Development and Characterization of Biostable Hydrogel Robotic Actuators for Implantable Devices: Tendon Actuated Gelatin Non-Invasive Diagnosis of Deep Vein Thrombosis to Expedite Treatment and Prevent Pulmonary Embolism During Gestation Development of an Epicardial Mapping Tank for Noninvasive Electrical Mapping of Ex Vivo Large Mammalian Hearts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1