{"title":"Performance assessment of single and dual loops discrete PR controllers with LCL filter for inverter-based distributed generation","authors":"H. M. El-Deeb, A. Elserougi, A. Abdel-Khalik, S. Ahmed, A. Massoud","doi":"10.1109/SPEEDAM.2014.6872120","DOIUrl":null,"url":null,"abstract":"Due to the rapid growth of the electric energy demands, the necessity of involvement of distributed generation (DG) to overcome this demand became a must. When distributed generation renewable energy sources are coupled to the grid through a DC-AC inverter, the injected currents to the grid should be characterized by high quality and low distortion. Many factors play an important role to produce high quality output beginning with the order of the passive filter used, type of controller used and last but not least the presence of distortions in the grid. This paper demonstrates the evaluation of performance, in normal and abnormal grid conditions, between single and dual loop control for the three phase inverter tied to the grid through a LCL passive filter and controlled with discrete proportional resonant (PR) controller, taking into account how filter parameters, control gains and sampling frequency would affect the dynamics of the system as well as its stability in order to perform adequate tuning. The concluded assumptions were simulated & verified through Matlab/Simulink.","PeriodicalId":344918,"journal":{"name":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Symposium on Power Electronics, Electrical Drives, Automation and Motion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEEDAM.2014.6872120","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Due to the rapid growth of the electric energy demands, the necessity of involvement of distributed generation (DG) to overcome this demand became a must. When distributed generation renewable energy sources are coupled to the grid through a DC-AC inverter, the injected currents to the grid should be characterized by high quality and low distortion. Many factors play an important role to produce high quality output beginning with the order of the passive filter used, type of controller used and last but not least the presence of distortions in the grid. This paper demonstrates the evaluation of performance, in normal and abnormal grid conditions, between single and dual loop control for the three phase inverter tied to the grid through a LCL passive filter and controlled with discrete proportional resonant (PR) controller, taking into account how filter parameters, control gains and sampling frequency would affect the dynamics of the system as well as its stability in order to perform adequate tuning. The concluded assumptions were simulated & verified through Matlab/Simulink.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于逆变器的分布式发电中带LCL滤波器的单环和双环离散PR控制器的性能评估
由于电力能源需求的快速增长,分布式发电(DG)参与的必要性,以克服这一需求成为必须。当分布式发电可再生能源通过直流-交流逆变器耦合到电网时,注入电网的电流应具有高质量和低畸变的特点。许多因素在产生高质量输出方面起着重要作用,从使用的无源滤波器的顺序、使用的控制器类型开始,最后但并非最不重要的是电网中存在的扭曲。本文演示了在正常和异常电网条件下,通过LCL无源滤波器和离散比例谐振(PR)控制器控制的三相逆变器的单环和双环控制之间的性能评估,考虑到滤波器参数,控制增益和采样频率如何影响系统的动力学及其稳定性,以便进行适当的调谐。通过Matlab/Simulink对所得假设进行了仿真验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A wireless controlled circuit for PV panel disconnection in case of fire Voltage stabilization in weak grids by high power charging stations Concepts for an integration of quick charging stations in weak power grids Some lab experiments on the control of an aircraft electrical landing gear Controller Hardware-In-the-Loop validation of a magnetic core saturation algorithm for fault ride-through evaluations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1