Roberta Piazza, Hareem Nisar, John Moore, S. Condino, M. Ferrari, V. Ferrari, T. Peters, E. Chen
{"title":"Towards electromagnetic tracking of J-tip guidewire: precision assessment of sensors during bending tests","authors":"Roberta Piazza, Hareem Nisar, John Moore, S. Condino, M. Ferrari, V. Ferrari, T. Peters, E. Chen","doi":"10.1117/12.2549764","DOIUrl":null,"url":null,"abstract":"Electromagnetic image guidance systems have emerged as more secure methods to improve the performance of several catheter-based minimally invasive surgical procedures. Small sensors are incorporated within catheters and guidewires in order to track and guide in real-time their position and orientation with a reduced intra- procedural radiation exposure and contrast agent injections. One of the major limits of these systems is related to the unsuitable sensorization strategy for the J-tip guidewires, due to the structural constraints of the sensor coils available on the market. In this work we present preliminary results on a sensors bending test in static conditions to assess whether and when the precision of the sensor remains unchanged and/or deteriorates. In the worst case, the highest standard deviation is less than 0:10 mm.","PeriodicalId":302939,"journal":{"name":"Medical Imaging: Image-Guided Procedures","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Imaging: Image-Guided Procedures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2549764","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
Electromagnetic image guidance systems have emerged as more secure methods to improve the performance of several catheter-based minimally invasive surgical procedures. Small sensors are incorporated within catheters and guidewires in order to track and guide in real-time their position and orientation with a reduced intra- procedural radiation exposure and contrast agent injections. One of the major limits of these systems is related to the unsuitable sensorization strategy for the J-tip guidewires, due to the structural constraints of the sensor coils available on the market. In this work we present preliminary results on a sensors bending test in static conditions to assess whether and when the precision of the sensor remains unchanged and/or deteriorates. In the worst case, the highest standard deviation is less than 0:10 mm.