Behavior of the corona current in coaxial systems with negative corona under controlled pressure conditions

J. A. Alarcón, F. Santamaria, F. Roman
{"title":"Behavior of the corona current in coaxial systems with negative corona under controlled pressure conditions","authors":"J. A. Alarcón, F. Santamaria, F. Roman","doi":"10.1109/SIPDA.2015.7339320","DOIUrl":null,"url":null,"abstract":"This paper studies the behavior of the corona effect in dry air and coaxial configuration for different pressure values. The study is conducted in a system of four parallel-connected coaxial cylinders placed inside a controlled pressure chamber. During the tests, DC current is measured through the coaxial system for various pressure values when a voltage, higher than the corona onset, is applied; then, a mathematical model that describes the behavior of the corona current as a function of pressure and applied voltage is obtained. The mathematical model accurately reproduces the behavior observed during the measurements.","PeriodicalId":296478,"journal":{"name":"2015 International Symposium on Lightning Protection (XIII SIPDA)","volume":"29 4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Symposium on Lightning Protection (XIII SIPDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIPDA.2015.7339320","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper studies the behavior of the corona effect in dry air and coaxial configuration for different pressure values. The study is conducted in a system of four parallel-connected coaxial cylinders placed inside a controlled pressure chamber. During the tests, DC current is measured through the coaxial system for various pressure values when a voltage, higher than the corona onset, is applied; then, a mathematical model that describes the behavior of the corona current as a function of pressure and applied voltage is obtained. The mathematical model accurately reproduces the behavior observed during the measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
控制压力条件下负电晕同轴系统的电晕电流行为
本文研究了不同压力值下干空气和同轴结构下电晕效应的特性。该研究是在一个由四个平行连接的同轴圆柱体组成的系统中进行的,这些圆柱体放置在一个受控的压力室中。在测试过程中,当施加高于电晕起始电压的电压时,通过同轴系统测量各种压力值下的直流电流;然后,得到了描述电晕电流随压力和外加电压变化的数学模型。数学模型准确地再现了测量过程中观察到的行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Lightning Disaster Risk assessment method in Colombia Experimental study on the surge protection of converters in direct-driven permanent-magnetic wind turbines Moon effect on lightning Soil resistivity behavior under high current density values using the Energy Balance method Design and calibration of an atmospheric electric field sensor with wireless comunication
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1