{"title":"Thermal comfort in air-conditioned learning environment","authors":"Siti Rohana Mohd Yatim, Meor Ahmad Mustaqim Meor Mohd Zain, Fairus Muhamad Darus, Z. S. Ismail","doi":"10.1109/ISESEE.2011.5977088","DOIUrl":null,"url":null,"abstract":"This paper appraises the thermal comfort condition of in air conditioned learning environment of the new learning campus in Universiti Teknologi MARA, Puncak Alam. The physical measurement and survey questionnaires have been thoroughly measured among the occupants (235 respondents) in four air conditioned classrooms along with four lecture theatres. The result shows relative humidity and air velocity are within the recommended limit while operative temperature for both classrooms and lecture theatres were below recommended limit. The calculated Prediction Mean Vote (PMV) — Predicted Percentage Dissatisfied (PPD) indices computed merely 29% has shown dissatisfaction towards learning environments. In addition, computed Thermal Sensation Vote (TSV) for classroom divulges that people remarked the learning environment for classroom and lecture theatre to be ‘slightly cool’. However, the mean value of thermal comfort based on Predictive Mean Vote (PMV) for classroom was −0.05, which indicate ‘neutral’ condition, whereas PMV value for lecture theatres was −0.62 which is ‘slightly cool’. Therefore, those findings show calculated thermal states have not necessarily correlate to occupant's desired thermal state.","PeriodicalId":105476,"journal":{"name":"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)","volume":"140 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 3rd International Symposium & Exhibition in Sustainable Energy & Environment (ISESEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISESEE.2011.5977088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

This paper appraises the thermal comfort condition of in air conditioned learning environment of the new learning campus in Universiti Teknologi MARA, Puncak Alam. The physical measurement and survey questionnaires have been thoroughly measured among the occupants (235 respondents) in four air conditioned classrooms along with four lecture theatres. The result shows relative humidity and air velocity are within the recommended limit while operative temperature for both classrooms and lecture theatres were below recommended limit. The calculated Prediction Mean Vote (PMV) — Predicted Percentage Dissatisfied (PPD) indices computed merely 29% has shown dissatisfaction towards learning environments. In addition, computed Thermal Sensation Vote (TSV) for classroom divulges that people remarked the learning environment for classroom and lecture theatre to be ‘slightly cool’. However, the mean value of thermal comfort based on Predictive Mean Vote (PMV) for classroom was −0.05, which indicate ‘neutral’ condition, whereas PMV value for lecture theatres was −0.62 which is ‘slightly cool’. Therefore, those findings show calculated thermal states have not necessarily correlate to occupant's desired thermal state.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
空调学习环境的热舒适性
本文对印度理工大学马拉马拉新校区空调学习环境的热舒适状况进行了评价。在四个空调教室和四个演讲厅中,对住户(235名受访者)进行了物理测量和调查问卷调查。结果表明,相对湿度和风速均在建议限值内,而教室和报告厅的工作温度均低于建议限值。计算出的预测平均投票(PMV) -预测不满意百分比(PPD)指数仅为29%,表明对学习环境不满意。此外,教室的热感觉投票(TSV)显示,人们认为教室和演讲厅的学习环境“稍微凉爽”。然而,基于预测平均投票(PMV)的教室热舒适平均值为- 0.05,表明“中性”状态,而演讲厅的PMV值为- 0.62,表明“略冷”状态。因此,这些发现表明计算的热状态不一定与居住者期望的热状态相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Training transfer: Training characteristic, training design and work environment evaluation Carbon dioxide sequestration at elevated temperature by pressure swing adsorption Performance analysis of 45.36 kWp grid-connected photovoltaic systems at Malaysia Green Technology Corporation Multitrophic system: Effect of different concentration of nutrient and pre-infested brinjal (Solanum melongena) on whitefly (Bemisia tabaci) population Screw-fixing damages and screw-holding performance in particleboard exposed to the kitchen environment in the selected area of Kuala Lumpur and Selangor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1