PLC based DC drive control using Modbus RTU communication for selected applications of sugar mill

K. N. Hittanagi, M. Ramesh, K. N. R. Kumar, S. Mahadeva
{"title":"PLC based DC drive control using Modbus RTU communication for selected applications of sugar mill","authors":"K. N. Hittanagi, M. Ramesh, K. N. R. Kumar, S. Mahadeva","doi":"10.1109/CCUBE.2017.8394156","DOIUrl":null,"url":null,"abstract":"DC Drives are serving in industries with their efficient motion control ability. These Drives can operate in Local Mode as well as in Overriding Control mode. In Local Mode the Drive is controlled by its control panel where as in Overriding Control mode, it can be controlled remotely by a Programmable Logic Controller (PLC). This PLC based control of Drive is essential for process control in industries like Sugar Mill. Further, this control can be employed using any of the industrial communication protocols which reduce the wiring complexity. Modbus Remote Terminal Unit (RTU) is one such protocol which is open, robust and widely used in industries because of its simplicity. Therefore the same protocol has been implemented in the presented work. This paper depicts initially about configuring a DC Drive (DCS800 of ABB) for Modbus RTU communication and a preliminary test to verify the proper working of intermediate components and cables by communicating the Drive with PC using Modscan32 software. Later, the PLC and Drive communication details and development of ladder program are presented. Further, the results obtained from testing PLC-Drive communication considering the two applications of Sugar Mill are put forth. These ensure the successful implementation of PLC-Drive communication. The applications considered are; speed raise and lower of a DC motor by PLC and secondly, achieving a speed pattern (speed versus time graph) required by a process of Centrifugal Machine in Sugar Mill.","PeriodicalId":443423,"journal":{"name":"2017 International Conference on Circuits, Controls, and Communications (CCUBE)","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 International Conference on Circuits, Controls, and Communications (CCUBE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCUBE.2017.8394156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

DC Drives are serving in industries with their efficient motion control ability. These Drives can operate in Local Mode as well as in Overriding Control mode. In Local Mode the Drive is controlled by its control panel where as in Overriding Control mode, it can be controlled remotely by a Programmable Logic Controller (PLC). This PLC based control of Drive is essential for process control in industries like Sugar Mill. Further, this control can be employed using any of the industrial communication protocols which reduce the wiring complexity. Modbus Remote Terminal Unit (RTU) is one such protocol which is open, robust and widely used in industries because of its simplicity. Therefore the same protocol has been implemented in the presented work. This paper depicts initially about configuring a DC Drive (DCS800 of ABB) for Modbus RTU communication and a preliminary test to verify the proper working of intermediate components and cables by communicating the Drive with PC using Modscan32 software. Later, the PLC and Drive communication details and development of ladder program are presented. Further, the results obtained from testing PLC-Drive communication considering the two applications of Sugar Mill are put forth. These ensure the successful implementation of PLC-Drive communication. The applications considered are; speed raise and lower of a DC motor by PLC and secondly, achieving a speed pattern (speed versus time graph) required by a process of Centrifugal Machine in Sugar Mill.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于PLC的直流驱动控制,采用Modbus RTU通信,选定糖厂应用
直流驱动器以其高效的运动控制能力服务于工业领域。这些驱动器可以在本地模式以及在覆盖控制模式下操作。在本地模式下,驱动器由其控制面板控制,而在覆盖控制模式下,它可以通过可编程逻辑控制器(PLC)远程控制。这种基于PLC的驱动控制对于糖厂等行业的过程控制至关重要。此外,这种控制可以使用任何减少布线复杂性的工业通信协议。Modbus远程终端单元(RTU)就是这样一种协议,由于其简单、开放、鲁棒性好,在工业中得到了广泛的应用。因此,本文采用了相同的协议。本文初步介绍了一种用于Modbus RTU通信的直流驱动器(ABB的DCS800)的配置,并通过Modscan32软件与PC机通信,初步验证了中间元件和电缆的正常工作。然后,给出了PLC与Drive的通信细节和梯形程序的开发。并结合糖厂的两种应用,给出了plc -驱动通信的测试结果。这些保证了PLC-Drive通信的成功实现。考虑的申请有:通过PLC控制直流电机的升降速度,实现糖厂离心机工艺所需的速度模式(速度与时间的关系图)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Wavelet based clutter reduction of GPR data Wire monopole antenna for low earth orbit satellite applications Fast turbo codes using sub-block based interleaver MEMS capacitive humidity sensor with plate array structure using polyimide sensing layer A study on application layer protocols used in IoT
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1