IEC 60060- 1 Requirements in Impulse Current Waveform Parameters

S. Sato, T. Harada, M. Hanai
{"title":"IEC 60060- 1 Requirements in Impulse Current Waveform Parameters","authors":"S. Sato, T. Harada, M. Hanai","doi":"10.1109/IPEC.2005.206932","DOIUrl":null,"url":null,"abstract":"There are IEC 60060-1 requirements on three impulse current waveforms. For the damped-oscillating waves, margins of the front time T1 and the time to half the peak T2 are 10 per cent whilst any value after the polarity reversal has to be less than 20 per cent of the peak value. Authors have tried to construct impulse current calibrator for reference measuring system, which would generate a waveform having the time parameters quite close to ideals. After numerous simulations in selecting values for circuit composing components, authors came to an impression that a damped-oscillating current generator whose output waveform has parameter values close to standard. In the paper, authors' \"impression\" is theoretically proved and mathematically possible margins are to be presented in detail.","PeriodicalId":164802,"journal":{"name":"2005 International Power Engineering Conference","volume":"60 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Power Engineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPEC.2005.206932","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

There are IEC 60060-1 requirements on three impulse current waveforms. For the damped-oscillating waves, margins of the front time T1 and the time to half the peak T2 are 10 per cent whilst any value after the polarity reversal has to be less than 20 per cent of the peak value. Authors have tried to construct impulse current calibrator for reference measuring system, which would generate a waveform having the time parameters quite close to ideals. After numerous simulations in selecting values for circuit composing components, authors came to an impression that a damped-oscillating current generator whose output waveform has parameter values close to standard. In the paper, authors' "impression" is theoretically proved and mathematically possible margins are to be presented in detail.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
IEC 60060- 1冲击电流波形参数要求
IEC 60060-1对三种脉冲电流波形有要求。对于阻尼振荡波,前时间T1和达到峰值T2一半的时间的边缘为10%,而极性反转后的任何值必须小于峰值的20%。作者尝试构建了一种用于参考测量系统的脉冲电流校准器,它产生的波形时间参数非常接近理想。通过对电路组成元件的数值选择进行了多次仿真,得出了一种输出波形参数值接近标准的阻尼振荡电流发生器。在本文中,作者的“印象”在理论上得到了证明,并在数学上给出了可能的边际。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The application of association rule mining in power system restoration The influence of model mismatch to power system calculation, part II: on the stability calculation Optimal participation of a microgrid to the energy market with an intelligent EMS An account of a modified lightning protection system for power stations An improved usage allocation method for deregulated transmission systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1