Proposal of new expressions for the calculation of section factor on structural steel columns in contact with walls

Fire Research Pub Date : 2019-10-11 DOI:10.4081/fire.2019.73
António J. M. Correia, P. Lopes, J. Rodrigues, J. Correia
{"title":"Proposal of new expressions for the calculation of section factor on structural steel columns in contact with walls","authors":"António J. M. Correia, P. Lopes, J. Rodrigues, J. Correia","doi":"10.4081/fire.2019.73","DOIUrl":null,"url":null,"abstract":"The fire resistance of a steel column is highly affected by the contact between the columns and the walls, leading in general to a favorable effect due to the reduction of temperatures. However, it leads to the Thermal Bowing effect, which is not more than a differential heating in the steel cross sections, causing an inversion of bending moments and an inversion of the deflections of the column. Thus, it is necessary to accurately assess the evolution of the temperature field in the cross section of the steel elements in contact with walls. In Eurocode 3 part 1-2, the structural design of steel elements in fire situation is performed with expressions for the calculation of the section factor of steel profiles, but different cases of positioning the columns and the surrounding walls could be considered as causing extremely high thermal gradients. In this paper, a new approach for the calculation of section factors for cases not included in table 4.2 of Eurocode 3, part 1- 2 are presented. This was achieved using numerical models with finite element modelling with the ABAQUS program, varying the cross-section of the columns, orientation of the web in relation to the walls, and the position and thickness of the walls, to achieve the desired section factors.","PeriodicalId":229102,"journal":{"name":"Fire Research","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4081/fire.2019.73","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The fire resistance of a steel column is highly affected by the contact between the columns and the walls, leading in general to a favorable effect due to the reduction of temperatures. However, it leads to the Thermal Bowing effect, which is not more than a differential heating in the steel cross sections, causing an inversion of bending moments and an inversion of the deflections of the column. Thus, it is necessary to accurately assess the evolution of the temperature field in the cross section of the steel elements in contact with walls. In Eurocode 3 part 1-2, the structural design of steel elements in fire situation is performed with expressions for the calculation of the section factor of steel profiles, but different cases of positioning the columns and the surrounding walls could be considered as causing extremely high thermal gradients. In this paper, a new approach for the calculation of section factors for cases not included in table 4.2 of Eurocode 3, part 1- 2 are presented. This was achieved using numerical models with finite element modelling with the ABAQUS program, varying the cross-section of the columns, orientation of the web in relation to the walls, and the position and thickness of the walls, to achieve the desired section factors.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
提出了与墙体接触钢柱截面系数计算的新表达式
钢柱的耐火性很大程度上受柱与墙之间接触的影响,由于温度的降低,通常会产生良好的效果。然而,它会导致热弯曲效应,这不仅仅是钢截面的不同加热,导致弯矩的反转和柱挠度的反转。因此,有必要准确地评估与壁接触的钢构件截面内温度场的演变。在欧洲规范3第1-2部分中,火灾情况下钢构件的结构设计是用钢型材截面系数的计算表达式进行的,但不同的情况下,柱和周围墙壁的定位可以考虑引起极高的热梯度。本文提出了一种计算欧洲规范3第1- 2部分表4.2中未包括的情况的截面系数的新方法。这是通过使用ABAQUS程序进行有限元建模的数值模型来实现的,通过改变柱的横截面、腹板相对于墙壁的方向以及墙壁的位置和厚度来实现所需的截面系数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
VIRGILE project: The concept of virtual fire resistance facility for the assessment of construction products performance Synthesis of silica nanoparticles to enhance the fire resistance of cement mortars Thermal properties of fired clay bricks from waste recycling. A review of studies Mechanical analysis of a portal steel frame when subjected to a post-earthquake fire Influence of different merging angles of pedestrian flows on evacuation time
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1