A candidate reference method for coupled sodium-water determination in human serum.

J D van Suijlen, C A Berrevoets, B Leijnse
{"title":"A candidate reference method for coupled sodium-water determination in human serum.","authors":"J D van Suijlen, C A Berrevoets, B Leijnse","doi":"10.1515/cclm.1990.28.11.817","DOIUrl":null,"url":null,"abstract":"A candidate reference method is described for coupled sodium-water determination based on ion-exchange sodium separation from the serum matrix followed by gravimetry as Na2SO4, and serum water determination by means of microwave evaporation. For sera with normal sodium and water contents, the mean relative standard deviation is 0.6% (0.8 mmol/l). Mean inaccuracy for the coupled sodium-water determination is -0.3% (0.4 mmol/l). The candidate reference method can be considered a reference method because the reference method value did not differ significantly from the definitive value, there is no known source for interferences or bias, and misinterpretation due to abnormal protein or lipid levels is excluded because serum sodium is determined on a plasma water basis. Sodium concentrations determined by the candidate reference method are used for comparing field methods with the candidate reference method. If the resulting regression equation is used in the calibration procedure, good correlation between all (in)direct field methods and the candidate reference method is ensured, and accurate results are produced. Results of proficiency testing show a good correlation between (in)direct field methods and the candidate reference method, because sera with approximately normal water contents are used.","PeriodicalId":15649,"journal":{"name":"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie","volume":"28 11","pages":"817-24"},"PeriodicalIF":0.0000,"publicationDate":"1990-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1515/cclm.1990.28.11.817","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/cclm.1990.28.11.817","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A candidate reference method is described for coupled sodium-water determination based on ion-exchange sodium separation from the serum matrix followed by gravimetry as Na2SO4, and serum water determination by means of microwave evaporation. For sera with normal sodium and water contents, the mean relative standard deviation is 0.6% (0.8 mmol/l). Mean inaccuracy for the coupled sodium-water determination is -0.3% (0.4 mmol/l). The candidate reference method can be considered a reference method because the reference method value did not differ significantly from the definitive value, there is no known source for interferences or bias, and misinterpretation due to abnormal protein or lipid levels is excluded because serum sodium is determined on a plasma water basis. Sodium concentrations determined by the candidate reference method are used for comparing field methods with the candidate reference method. If the resulting regression equation is used in the calibration procedure, good correlation between all (in)direct field methods and the candidate reference method is ensured, and accurate results are produced. Results of proficiency testing show a good correlation between (in)direct field methods and the candidate reference method, because sera with approximately normal water contents are used.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人血清中钠-水偶联测定的候选参考方法。
描述了一种基于离子交换分离血清基质钠,然后用Na2SO4重量法测定,微波蒸发法测定血清水分的钠-水耦合测定候选参考方法。对于钠和水含量正常的血清,平均相对标准偏差为0.6% (0.8 mmol/l)。钠-水耦合测定的平均误差为-0.3% (0.4 mmol/l)。候选参考方法可以被视为参考方法,因为参考方法值与确定值没有显著差异,没有已知的干扰或偏差来源,并且由于血清钠是在血浆水基础上测定的,因此排除了由于异常蛋白质或脂质水平引起的误解。用候选参比法测定的钠浓度对现场法和候选参比法进行了比较。如果在校准过程中使用得到的回归方程,则确保所有直接场方法与候选参考方法之间具有良好的相关性,并产生准确的结果。熟练程度测试的结果显示直接场法和候选参考方法之间有很好的相关性,因为使用的是近似正常含水量的血清。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Memorandum for the evaluation of diagnostic measures. An extraction/enzymatic procedure for serum cholesterol measurement: evaluation of performance characteristics. CA 19-9 and CA 125 determination by immunoluminometric assay. The effect of pretreatment of saliva on steroid hormone concentrations. Multicentre evaluation of an enzyme-immunoassay for cortisol determination.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1