Adiabatic Effectiveness and Thermal Field Measurements of a Shaped Hole in the Showerhead of a Model Turbine Blade

J. Moore, Matthew J. Horner, D. Bogard
{"title":"Adiabatic Effectiveness and Thermal Field Measurements of a Shaped Hole in the Showerhead of a Model Turbine Blade","authors":"J. Moore, Matthew J. Horner, D. Bogard","doi":"10.1115/GT2020-15016","DOIUrl":null,"url":null,"abstract":"\n Few published studies incorporating shaped hole designs in the leading-edge region, or showerhead, of turbine airfoils have been performed; but among them is the indication that shaped holes may offer an improvement in coolant performance compared to cylindrical holes. A shaped hole was designed with the goal of high performance in the showerhead. The performance and physical behavior of this shaped hole design was studied in comparison to a traditional cylindrical hole design in a series of experiments. The geometries were built into the leading edge of a scaled-up turbine blade model for testing in a low-speed simulated linear cascade. To accomplish an engine-representative test environment, a nominally 5% approach turbulence level was used for this study. Adiabatic effectiveness as a function of coolant injection rate was measured for the two designs using infrared thermography. In addition, off-the-wall thermal field measurements were performed for each hole geometry in the leading-edge region. It was found that the shaped hole offered ∼20–100% higher performance in terms of adiabatic effectiveness depending on the coolant injection rate. The thermal field measurements suggested that this was due to the better attachment of the jets exiting the shaped holes, the momenta of which were effectively reduced by the diffusers.","PeriodicalId":147616,"journal":{"name":"Volume 7B: Heat Transfer","volume":"61 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 7B: Heat Transfer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/GT2020-15016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Few published studies incorporating shaped hole designs in the leading-edge region, or showerhead, of turbine airfoils have been performed; but among them is the indication that shaped holes may offer an improvement in coolant performance compared to cylindrical holes. A shaped hole was designed with the goal of high performance in the showerhead. The performance and physical behavior of this shaped hole design was studied in comparison to a traditional cylindrical hole design in a series of experiments. The geometries were built into the leading edge of a scaled-up turbine blade model for testing in a low-speed simulated linear cascade. To accomplish an engine-representative test environment, a nominally 5% approach turbulence level was used for this study. Adiabatic effectiveness as a function of coolant injection rate was measured for the two designs using infrared thermography. In addition, off-the-wall thermal field measurements were performed for each hole geometry in the leading-edge region. It was found that the shaped hole offered ∼20–100% higher performance in terms of adiabatic effectiveness depending on the coolant injection rate. The thermal field measurements suggested that this was due to the better attachment of the jets exiting the shaped holes, the momenta of which were effectively reduced by the diffusers.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
模型涡轮淋喷头形孔的绝热效能及热场测量
很少发表的研究纳入在前缘区域的形孔设计,或淋浴头,涡轮翼型已经执行;但其中有迹象表明,与圆柱形孔相比,形孔可能提供更好的冷却剂性能。为了提高淋浴喷头的性能,设计了一个形孔。通过一系列实验,对比研究了该型孔设计与传统圆柱孔设计的性能和物理特性。这些几何形状被内置到一个按比例放大的涡轮叶片模型的前缘,用于低速模拟线性叶栅的测试。为了完成一个具有发动机代表性的测试环境,本研究使用了名义上5%的接近湍流水平。采用红外热像仪测量了两种设计的绝热效率随冷却剂喷射速率的变化。此外,还对前缘区域的每个孔的几何形状进行了壁外热场测量。研究发现,根据冷却剂注入速度的不同,形状孔的绝热效率提高了~ 20-100%。热场测量表明,这是由于射流更好的附着,射流的动量被扩散器有效地降低了。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Film Cooling Performance on Turbine Blade Suction Side With Various Film Cooling Hole Arrangements Evaluation of a Machine Learning Turbulence Model in a Square Transverse Jet in Crossflow LES Study of the Effects of Oscillations in the Main Flow on Film Cooling Effects of Film Hole Shape and Turbulence Intensity on the Thermal Field Downstream of Single Row Film Holes Experimental Study of Full Coverage Film Cooling Effectiveness for a Turbine Blade With Compound Shaped Holes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1