Confectionary coating using an electrohydrodynamic system

S. Barringer, Kumala Marthina
{"title":"Confectionary coating using an electrohydrodynamic system","authors":"S. Barringer, Kumala Marthina","doi":"10.1109/ICDL.2011.6015435","DOIUrl":null,"url":null,"abstract":"In the chocolate coating industry, cocoa butter is a high value ingredient. Due to high cost, shortage of supply and blooming, hard butters are frequently used as cocoa butter replacers. An electrohydrodynamic system (EHD), which forms fine droplets with a relatively narrow size distribution, may be beneficial in confectionary coating to reduce cost and to increase quality because complete and even coverage can be achieved. The objective of this research is to optimize the use of EHD by altering the resistivity, viscosity and yield stress of different types of confectionery coating using lecithin. Non-EHD and EHD coating systems using confectionary coating made of cocoa butter equivalent, lauric cocoa butter or cocoa butter with different percentages of lecithin were analyzed. Droplet size, thickness of coating and minimum flow rate to produce complete coverage was measured. The voltage supplied for EHD coating system was 25kV. As lecithin increased, resistivity, viscosity and yield stress of samples decreased. Lower resistivity, viscosity and yield stress samples produced smaller droplet size, thinner coating and higher minimum flow rate. EHD coating is more efficient than non-EHD coating because more even and complete coverage can be achieved as fine droplets are produced and distributed during coating. The droplet size was significantly smaller for samples sprayed with EHD compared to non-EHD. The thickness was significantly lower under EHD and the minimum flow rate to get complete coverage with EHD was greater because EHD coating tends to spread over a wider area. Under EHD coating, samples with lower resistivity produced smaller droplet size and lower thickness, which is important to reduce cost and increase quality of coated food products.","PeriodicalId":364451,"journal":{"name":"2011 IEEE International Conference on Dielectric Liquids","volume":"107 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Dielectric Liquids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDL.2011.6015435","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the chocolate coating industry, cocoa butter is a high value ingredient. Due to high cost, shortage of supply and blooming, hard butters are frequently used as cocoa butter replacers. An electrohydrodynamic system (EHD), which forms fine droplets with a relatively narrow size distribution, may be beneficial in confectionary coating to reduce cost and to increase quality because complete and even coverage can be achieved. The objective of this research is to optimize the use of EHD by altering the resistivity, viscosity and yield stress of different types of confectionery coating using lecithin. Non-EHD and EHD coating systems using confectionary coating made of cocoa butter equivalent, lauric cocoa butter or cocoa butter with different percentages of lecithin were analyzed. Droplet size, thickness of coating and minimum flow rate to produce complete coverage was measured. The voltage supplied for EHD coating system was 25kV. As lecithin increased, resistivity, viscosity and yield stress of samples decreased. Lower resistivity, viscosity and yield stress samples produced smaller droplet size, thinner coating and higher minimum flow rate. EHD coating is more efficient than non-EHD coating because more even and complete coverage can be achieved as fine droplets are produced and distributed during coating. The droplet size was significantly smaller for samples sprayed with EHD compared to non-EHD. The thickness was significantly lower under EHD and the minimum flow rate to get complete coverage with EHD was greater because EHD coating tends to spread over a wider area. Under EHD coating, samples with lower resistivity produced smaller droplet size and lower thickness, which is important to reduce cost and increase quality of coated food products.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
采用电流体动力系统的糖果涂层
在巧克力涂层行业,可可脂是一种高价值的成分。由于成本高,供应短缺和开花,硬脂经常被用作可可脂的替代品。电流体动力系统(EHD)可以形成具有相对狭窄尺寸分布的细液滴,可以实现完全和均匀的覆盖,从而有利于降低成本和提高质量。本研究的目的是通过改变不同类型的卵磷脂糖果涂层的电阻率、粘度和屈服应力来优化EHD的使用。采用可可脂当量、月桂可可脂和可可脂添加不同百分比的卵磷脂制成糖果涂层,对非EHD和EHD涂层体系进行了分析。测量了液滴大小、涂层厚度和产生完全覆盖的最小流速。EHD涂层系统供电电压为25kV。随着卵磷脂的增加,样品的电阻率、粘度和屈服应力降低。电阻率、粘度和屈服应力较低的样品,液滴尺寸更小,涂层更薄,最小流速更高。EHD涂层比非EHD涂层效率更高,因为在涂层过程中可以产生和分布细小的液滴,从而实现更均匀和完整的覆盖。与未喷EHD的样品相比,喷EHD的样品的液滴尺寸明显更小。EHD涂层的厚度明显较低,EHD涂层完全覆盖的最小流速较大,因为EHD涂层往往覆盖更大的区域。在EHD涂层下,电阻率较低的样品可以产生更小的液滴尺寸和更低的厚度,这对降低成本和提高涂层食品的质量具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Spectra emitted by helium excited by corona discharge Review of Kraft paper/natural ester fluid insulation system aging Surface treeing on pressboard barriers in synthetic and natural ester liquids under AC stress Partial discharges and light emission from ceramic substrates embedded in liquids and gels Time-dynamic oxidation stability studies of mineral insulating oils
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1