Inertia effect and load sharing capability of grid forming converters connected to a transmission grid

T. Qoria, F. Gruson, F. Colas, G. Denis, T. Prévost, X. Guillaud
{"title":"Inertia effect and load sharing capability of grid forming converters connected to a transmission grid","authors":"T. Qoria, F. Gruson, F. Colas, G. Denis, T. Prévost, X. Guillaud","doi":"10.1049/CP.2019.0079","DOIUrl":null,"url":null,"abstract":"The virtual synchronous machine concept (VSM) has been developed initially to reproduce the synchronous machine stabilizing effect by providing inertia with the emulation of swing equation, whereas droop control is developed initially to ensure load sharing and has no inertia. An introduction of a low pass filter to droop control has been motivated to filter the active power measurement and ensures a time decoupling with the inner control loops, whereas, this low-pass filter can also provide inertia to the system. This functionality is limited due to its negative impact on the active power dynamic. This paper proposes an analysis of the conventional droop control by showing its limitations and proposes an improved inertial droop control that allows providing the inertia to the system and ensures a good dynamic behavior of the active power at once in simple manner, and without modifying the load sharing capability. The results obtained are compared to the conventional method (Droop control and VSM) in various topologies in order to show the relevance of the proposed method.","PeriodicalId":362400,"journal":{"name":"15th IET International Conference on AC and DC Power Transmission (ACDC 2019)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"34","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"15th IET International Conference on AC and DC Power Transmission (ACDC 2019)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/CP.2019.0079","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 34

Abstract

The virtual synchronous machine concept (VSM) has been developed initially to reproduce the synchronous machine stabilizing effect by providing inertia with the emulation of swing equation, whereas droop control is developed initially to ensure load sharing and has no inertia. An introduction of a low pass filter to droop control has been motivated to filter the active power measurement and ensures a time decoupling with the inner control loops, whereas, this low-pass filter can also provide inertia to the system. This functionality is limited due to its negative impact on the active power dynamic. This paper proposes an analysis of the conventional droop control by showing its limitations and proposes an improved inertial droop control that allows providing the inertia to the system and ensures a good dynamic behavior of the active power at once in simple manner, and without modifying the load sharing capability. The results obtained are compared to the conventional method (Droop control and VSM) in various topologies in order to show the relevance of the proposed method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
并网变流器的惯性效应与负荷分担能力
虚拟同步机概念(VSM)是为了通过提供摆动方程仿真的惯性来再现同步机的稳定效果而初步提出的,而下垂控制则是为了保证负载共享且无惯性而初步提出的。引入低通滤波器用于下垂控制,以滤波有功功率测量并确保与内部控制回路的时间解耦,然而,该低通滤波器也可以为系统提供惯性。由于其对有功功率动态的负面影响,该功能受到限制。本文分析了传统的惯性下垂控制方法的局限性,提出了一种改进的惯性下垂控制方法,可以在不改变负荷分担能力的情况下,以简单的方式向系统提供惯性,同时保证有功功率具有良好的动态特性。将得到的结果与传统方法(下垂控制和VSM)在各种拓扑结构下进行比较,以显示所提出方法的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Protection and pole voltage rebalancing for pole-to-ground faults in symmetrical monopolar HVDC grids Assessment of Passive Islanding Detection Methods for DC Microgrids Coordination of Mechanical DCCBs and Temporary Blocking of Half Bridge MMC Investigation of the Impact of Interoperability of Voltage Source Converters on HVDC Grid Fault Behaviour Small signal state space model of the frequency-dependent DC cable based on direct vector fitting
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1