{"title":"Partial discharge and breakdown behavior of enamel-insulated copper conductors in carbon powder","authors":"D. Taylor, H. Hiziroglu, P. H. Foss","doi":"10.1109/CEIDP.2013.6747098","DOIUrl":null,"url":null,"abstract":"It is clear that during the manufacturing of the windings of an electric motor, enamel-insulated copper conductors are subjected to mechanical strain. The electrical performance of the enamel insulation could be adversely affected by this mechanical strain. Partial discharge inception voltage (PDIV) is a useful tool for comparing the performance of insulations. Therefore, PDIV tests along with breakdown voltage tests were performed for evaluating the effect of different levels of tensile-strain on the electrical properties of the enamel insulation of the copper conductor. In a previous work the enamel insulation was tested between two parallel-plate electrodes. In this study, however, unstrained and tensile-strained, enamel-insulated, copper conductors with rectangular cross-section were investigated and compared for their breakdown voltages and partial discharge behavior in a carbon powder medium.","PeriodicalId":393969,"journal":{"name":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"89 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2013.6747098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
It is clear that during the manufacturing of the windings of an electric motor, enamel-insulated copper conductors are subjected to mechanical strain. The electrical performance of the enamel insulation could be adversely affected by this mechanical strain. Partial discharge inception voltage (PDIV) is a useful tool for comparing the performance of insulations. Therefore, PDIV tests along with breakdown voltage tests were performed for evaluating the effect of different levels of tensile-strain on the electrical properties of the enamel insulation of the copper conductor. In a previous work the enamel insulation was tested between two parallel-plate electrodes. In this study, however, unstrained and tensile-strained, enamel-insulated, copper conductors with rectangular cross-section were investigated and compared for their breakdown voltages and partial discharge behavior in a carbon powder medium.