[Radiographic evaluation of 12% Au-Ag-Pd alloy cast lower denture plates constructed by dental student as a laboratory exercise].

M Miyao, M Yamauchi, M Sakai, M Nishizawa, M Shimizu, J Kawano
{"title":"[Radiographic evaluation of 12% Au-Ag-Pd alloy cast lower denture plates constructed by dental student as a laboratory exercise].","authors":"M Miyao,&nbsp;M Yamauchi,&nbsp;M Sakai,&nbsp;M Nishizawa,&nbsp;M Shimizu,&nbsp;J Kawano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We evaluated 12% Au-Ag-Pd alloy cast lower denture plates prepared by dental students in laboratory exercises for casting defects. First, we determined the most suitable exposure conditions for nondestructive radiographic test of 12% Au-Ag-Pd alloy. Subsequently, 130 plates were nondestructively evaluated by radiography under the most suitable exposure conditions. In radiographic testing using X-Omat RP films (Eastman Kodak Co.) and X-Omatic Fine Screen (Eastman Kodak Co.), the most suitable exposure conditions involved a target-to-film distance of 1.9 m, tube voltage of 148 Kvp, tube current of 10 mA, and exposure time of 1.5 sec. Preliminary radiographic examination of artificial casting defects revealed semispherical defects in the diameter of 0.25 mm in 1.6 mm-thick 12% Au-Ag-Pd alloy plates and detects of 0.26 mm in 2.4 mm thick plates. In the 130 cast plates, 56 casting defects were detected. These defects were found at the left webbing part in 40 (30.8%), right webbing part in 36 (27.7%), lingual bar in 7 (5.4%), I-bar in 4 (3.0%), and at other regions of the metal frames in 3 (2.3%) cases. These results indicate that nondestructive radiographic testing is as effective in detection of casting defects in 12% Au-Ag-Pd alloy cast plates as it is in Co-Cr and Ni-Cr alloy plates. This method was also found to be effective in evaluation of the practice metal frames constructed by dental students.</p>","PeriodicalId":12643,"journal":{"name":"Gifu Shika Gakkai zasshi = The Journal of Gifu Dental Society","volume":"17 2","pages":"516-24"},"PeriodicalIF":0.0000,"publicationDate":"1990-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gifu Shika Gakkai zasshi = The Journal of Gifu Dental Society","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We evaluated 12% Au-Ag-Pd alloy cast lower denture plates prepared by dental students in laboratory exercises for casting defects. First, we determined the most suitable exposure conditions for nondestructive radiographic test of 12% Au-Ag-Pd alloy. Subsequently, 130 plates were nondestructively evaluated by radiography under the most suitable exposure conditions. In radiographic testing using X-Omat RP films (Eastman Kodak Co.) and X-Omatic Fine Screen (Eastman Kodak Co.), the most suitable exposure conditions involved a target-to-film distance of 1.9 m, tube voltage of 148 Kvp, tube current of 10 mA, and exposure time of 1.5 sec. Preliminary radiographic examination of artificial casting defects revealed semispherical defects in the diameter of 0.25 mm in 1.6 mm-thick 12% Au-Ag-Pd alloy plates and detects of 0.26 mm in 2.4 mm thick plates. In the 130 cast plates, 56 casting defects were detected. These defects were found at the left webbing part in 40 (30.8%), right webbing part in 36 (27.7%), lingual bar in 7 (5.4%), I-bar in 4 (3.0%), and at other regions of the metal frames in 3 (2.3%) cases. These results indicate that nondestructive radiographic testing is as effective in detection of casting defects in 12% Au-Ag-Pd alloy cast plates as it is in Co-Cr and Ni-Cr alloy plates. This method was also found to be effective in evaluation of the practice metal frames constructed by dental students.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[牙科学生制作的12% Au-Ag-Pd合金铸造下义齿板的x线摄影评价作为实验室练习]。
我们对牙科学生在实验室练习中制备的12% Au-Ag-Pd合金铸造下义齿板的铸造缺陷进行了评估。首先,我们确定了12% Au-Ag-Pd合金无损射线检测的最合适暴露条件。随后,在最合适的曝光条件下,用射线照相法对130个板进行无损评价。在X-Omat RP膜(伊士曼柯达公司)和X-Omatic Fine Screen(伊士曼柯达公司)的射线照相测试中,最合适的曝光条件是靶到膜的距离为1.9 m,管电压为148 Kvp,管电流为10 mA,曝光时间为1.5秒。人工铸造缺陷的初步射线照相检查显示,在1.6 mm厚的12% Au-Ag-Pd合金板上,直径为0.25 mm的半球形缺陷,在2.4 mm厚的板上,检测到0.26 mm的缺陷。在130个铸板中,检测出56个铸造缺陷。其中左侧带带部40例(30.8%),右侧带带部36例(27.7%),舌条7例(5.4%),i形条4例(3.0%),金属框架其他部位3例(2.3%)。这些结果表明,射线无损检测对12% Au-Ag-Pd合金铸板的铸造缺陷的检测效果与对Co-Cr和Ni-Cr合金铸板的检测效果一样好。该方法也被发现是有效的评估实习金属框架的牙科学生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
ウシガエル舌の茸状乳頭内の Substance P, Vasoactive intestinal polypeptide, チロシン水酸化酵素含有神経線維の起源と分布についての免疫組織化学的研究 味識別に対する嗅覚の影響 : 行動学的・電気生理学的研究 [Effect of local anesthetics on intracellular calcium messenger system]. [A case report of anterior crowding treated without extraction]. [A case of maxillary protrusion].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1