{"title":"[Basic investigation using K6 diagnostic system. 3. Fabrication of the apparatus wearing a Sensor Alley and the evaluation of its accuracy].","authors":"E Aida, S Imamura, K Kurosu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Unlabelled: </strong>An investigation was undertaken to evaluated the accuracy of Sensor Alley, a mandibular movement analyser: K6 Diagnostic System EX with a newly designed auxiliary apparatus.</p><p><strong>Results: </strong>1) The errors in the values of the standard Sensor Alley were 4.8 mm for the VER-coordinate, 5.0 mm for the AP-coordinate and 3.0 mm for LA-coordinate. 2) The errors of the AP-coordinate were bigger than those of the VER and LA-coordinates. 3) The errors in the values of the standard Sensor Alley fitted with a newly designed auxiliary apparatus were 0.9 mm for the VER-coordinate, 2.0 mm for the AP-coordinate and 1.1 mm for the LA-coordinate. 4) The results led to the conclusion that this newly designed auxiliary apparatus was useful for various studies on mandibular movement used with the K6 Diagnostic System EX.</p>","PeriodicalId":75458,"journal":{"name":"Aichi Gakuin Daigaku Shigakkai shi","volume":"28 3","pages":"797-802"},"PeriodicalIF":0.0000,"publicationDate":"1990-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Aichi Gakuin Daigaku Shigakkai shi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Unlabelled: An investigation was undertaken to evaluated the accuracy of Sensor Alley, a mandibular movement analyser: K6 Diagnostic System EX with a newly designed auxiliary apparatus.
Results: 1) The errors in the values of the standard Sensor Alley were 4.8 mm for the VER-coordinate, 5.0 mm for the AP-coordinate and 3.0 mm for LA-coordinate. 2) The errors of the AP-coordinate were bigger than those of the VER and LA-coordinates. 3) The errors in the values of the standard Sensor Alley fitted with a newly designed auxiliary apparatus were 0.9 mm for the VER-coordinate, 2.0 mm for the AP-coordinate and 1.1 mm for the LA-coordinate. 4) The results led to the conclusion that this newly designed auxiliary apparatus was useful for various studies on mandibular movement used with the K6 Diagnostic System EX.
未标记:进行了一项调查,以评估Sensor Alley的准确性,这是一种下颌运动分析仪:K6诊断系统EX与新设计的辅助设备。结果:1)标准Sensor Alley值在ver坐标下误差4.8 mm, ap坐标下误差5.0 mm, la坐标下误差3.0 mm。2) ap -坐标误差大于VER和la -坐标误差。3)安装新设计的辅助装置后,标准Sensor Alley的值误差为ver坐标0.9 mm, ap坐标2.0 mm, la坐标1.1 mm。4)结果表明,这种新设计的辅助器械可用于与K6诊断系统EX配合使用的各种下颌运动研究。