FAULT CURRENT MANAGEMENT UNDER HIGH PENETRATION OF DISTRIBUTED GENERATION IN SMART GRIDS

M. Gabr, T. Megahed, S. Abdelkader
{"title":"FAULT CURRENT MANAGEMENT UNDER HIGH PENETRATION OF DISTRIBUTED GENERATION IN SMART GRIDS","authors":"M. Gabr, T. Megahed, S. Abdelkader","doi":"10.1049/icp.2021.1391","DOIUrl":null,"url":null,"abstract":"This paper introduces a new technique for mitigating the impact of Distributed Generation (DG) on fault current in radial distribution systems. The proposed approach employs the power electronics interface to control the DG fault current contribution. For this purpose, the power converter control DG current phase angle to achieve a reduction in total fault current magnitude. The appropriate control of DG current phase angle can limit the total fault current magnitude to the original value without DG; hence effectively mitigate the impact of adding DG. The evaluation of the proposed technique illustrates the validity of the proposed method for the management of the fault current magnitude.","PeriodicalId":223615,"journal":{"name":"The 9th Renewable Power Generation Conference (RPG Dublin Online 2021)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The 9th Renewable Power Generation Conference (RPG Dublin Online 2021)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1049/icp.2021.1391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper introduces a new technique for mitigating the impact of Distributed Generation (DG) on fault current in radial distribution systems. The proposed approach employs the power electronics interface to control the DG fault current contribution. For this purpose, the power converter control DG current phase angle to achieve a reduction in total fault current magnitude. The appropriate control of DG current phase angle can limit the total fault current magnitude to the original value without DG; hence effectively mitigate the impact of adding DG. The evaluation of the proposed technique illustrates the validity of the proposed method for the management of the fault current magnitude.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
智能电网分布式发电高渗透下的故障电流管理
介绍了一种减轻径向配电系统中分布式电源对故障电流影响的新技术。该方法采用电力电子接口控制DG故障电流贡献。为此,功率变换器控制DG电流相位角,以达到减小总故障电流大小的目的。适当控制DG电流相位角,可以将故障总电流限制在无DG时的原值;从而有效减轻添加DG的影响。通过对该方法的评价,验证了该方法对故障电流大小管理的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
EirGrid's Met Mast and Alternatives Study Fast Frequency Response Provision from Commercial Demand Response, from Scheduling to Stability in Power Systems IMPACT OF FAST WIND FLUCTUATIONS ON THE PROFIT OF A WIND POWER PRODUCER JOINTLY TRADING IN ENERGY AND RESERVE MARKETS A FLEXIBLE REAL TIME NETWORK MODEL FOR EVALUATING HVDC SYSTEMS' IMPACT ON AC PROTECTION PERFORMANCE IMPACT OF SYSTEM STRENGTH AND HVDC CONTROL STRATEGIES ON DISTANCE PROTECTION PERFORMANCE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1