Performance analysis of distance protection using different impedance calculation methods

Mohit Sharma, V. Shanmugasundaram
{"title":"Performance analysis of distance protection using different impedance calculation methods","authors":"Mohit Sharma, V. Shanmugasundaram","doi":"10.1109/CPRE.2018.8349814","DOIUrl":null,"url":null,"abstract":"Various combinations of voltages and currents are possible in the power system in an event of fault. Distance relays use these voltage and current phasors, obtained from PTs and CTs, to calculate impedance. The relay operates when the calculated impedance is below the reach or set impedance. The operation can be better understood when plotted on an impedance plane. Mho circles and quadrilateral characteristic are essentially the most popular characteristics used all across the world since they are inherently directional and provide well defined reach with minimal over reaching and under reaching errors. All the impedance points that lie within the characteristic are considered operating points.","PeriodicalId":285875,"journal":{"name":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 71st Annual Conference for Protective Relay Engineers (CPRE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2018.8349814","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Various combinations of voltages and currents are possible in the power system in an event of fault. Distance relays use these voltage and current phasors, obtained from PTs and CTs, to calculate impedance. The relay operates when the calculated impedance is below the reach or set impedance. The operation can be better understood when plotted on an impedance plane. Mho circles and quadrilateral characteristic are essentially the most popular characteristics used all across the world since they are inherently directional and provide well defined reach with minimal over reaching and under reaching errors. All the impedance points that lie within the characteristic are considered operating points.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用不同阻抗计算方法分析距离保护的性能
在发生故障的情况下,电力系统中电压和电流的各种组合是可能的。距离继电器使用从PTs和ct获得的电压和电流相量来计算阻抗。当计算阻抗低于到达或设定阻抗时,继电器工作。当绘制在阻抗平面上时,可以更好地理解操作。Mho圆和四边形特性本质上是世界上最受欢迎的特性,因为它们具有固有的方向性,并且提供了良好的定义,最小的过伸和过伸误差。所有在特性范围内的阻抗点都被认为是工作点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Correlating protective relay reports for system-wide, post-event analysis Back to the basics — Event analysis using symmetrical components Cyber security — Securing the protection and control relay communication in substation Communications assisted islanding detection: Contrasting direct transfer trip and phase comparison methods Applying intelligent fast load shed using IEC 61850 GOOSE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1