A modified CIGRE HVDC benchmark model for 60 Hz applications

James Schwartz, E. Rahimi, H. Zareipour
{"title":"A modified CIGRE HVDC benchmark model for 60 Hz applications","authors":"James Schwartz, E. Rahimi, H. Zareipour","doi":"10.1109/NAPS.2014.6965411","DOIUrl":null,"url":null,"abstract":"This paper proposes a 60 Hz equivalent to the CIGRE benchmark model (CBM) for HVDC control studies. Component configuration and system impedances of the PSCAD/EMTDC implementation of the CBM are modified to arrive at the 60 Hz equivalent model. These parameter changes are discussed and validation is given. Simulations are conducted in steady state and compared to that of the CBM. The response of the proposed equivalent to a current order step-response and AC faults are compared to that of the CBM. The performance comparisons match closely and this paper concludes that the proposed 60 Hz equivalent is adequate for use when running simulations that require an HVDC benchmark model be connected to a representation of a 60 Hz AC network.","PeriodicalId":421766,"journal":{"name":"2014 North American Power Symposium (NAPS)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 North American Power Symposium (NAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NAPS.2014.6965411","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper proposes a 60 Hz equivalent to the CIGRE benchmark model (CBM) for HVDC control studies. Component configuration and system impedances of the PSCAD/EMTDC implementation of the CBM are modified to arrive at the 60 Hz equivalent model. These parameter changes are discussed and validation is given. Simulations are conducted in steady state and compared to that of the CBM. The response of the proposed equivalent to a current order step-response and AC faults are compared to that of the CBM. The performance comparisons match closely and this paper concludes that the proposed 60 Hz equivalent is adequate for use when running simulations that require an HVDC benchmark model be connected to a representation of a 60 Hz AC network.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
60 Hz应用的改进CIGRE HVDC基准模型
本文提出了一个60 Hz等效CIGRE基准模型(CBM)用于高压直流控制研究。修改了CBM的PSCAD/EMTDC实现的组件配置和系统阻抗,以达到60 Hz等效模型。讨论了这些参数的变化,并给出了验证。在稳态下进行了仿真,并与CBM进行了比较。将所提出的等效电流阶跃响应和交流故障的响应与CBM的响应进行了比较。性能比较非常接近,本文得出的结论是,当运行需要将HVDC基准模型连接到60 Hz交流网络表示的模拟时,所提出的60 Hz等效功率足以使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Addressing cyber security for the oil, gas and energy sector Investigation of voltage stability in three-phase unbalanced distribution systems with DG using modal analysis technique Dynamic Remedial Action Scheme using online transient stability analysis Implementing a real-time cyber-physical system test bed in RTDS and OPNET Size reduction of permanent magnet generators for wind turbines with higher energy density permanent magnets
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1