Voltage-Stability Monitoring Using Wide-Area Measurement Systems

B. Genet, J. Maun
{"title":"Voltage-Stability Monitoring Using Wide-Area Measurement Systems","authors":"B. Genet, J. Maun","doi":"10.1109/PCT.2007.4538573","DOIUrl":null,"url":null,"abstract":"A new monitoring method based on a wide-area network of Phaser Measurement Units (PMU) is proposed. This tool detects on-line and in real-time an incipient voltage instability in the power system. A geographical visualization is introduced to monitor efficiently the state of the network. The method is general and can be implemented in any part of a network prone to voltage instability. It can be used to trigger corrective actions to avoid a collapse. The hypotheses and the results of the new method will be discussed in regard with those given by the Thevenin's equivalent computed at the load bus.","PeriodicalId":356805,"journal":{"name":"2007 IEEE Lausanne Power Tech","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"29","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Lausanne Power Tech","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCT.2007.4538573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

Abstract

A new monitoring method based on a wide-area network of Phaser Measurement Units (PMU) is proposed. This tool detects on-line and in real-time an incipient voltage instability in the power system. A geographical visualization is introduced to monitor efficiently the state of the network. The method is general and can be implemented in any part of a network prone to voltage instability. It can be used to trigger corrective actions to avoid a collapse. The hypotheses and the results of the new method will be discussed in regard with those given by the Thevenin's equivalent computed at the load bus.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用广域测量系统的电压稳定性监测
提出了一种基于相位测量单元(PMU)广域网的新型监测方法。该工具在线和实时检测电力系统的初期电压不稳定。为了有效地监控网络状态,引入了地理可视化技术。该方法具有通用性,可应用于电网中电压不稳定的任何部分。它可以用来触发纠正措施,以避免崩溃。新方法的假设和结果将与在负载母线上计算的Thevenin等效给出的假设和结果进行讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Northeast Asia Power Interconnection Routs and Representative Studies in South Korea PSO-based Hybrid Generating System Design Incorporating Reliability Evaluation and Generation/Load Forecasting Actual Problems Of The Distribution Cable Networks In Germany - Ageing And Structural Impact On The Reliability Study on Power Quality Control in Multiple Renewable Energy Hybrid MicroGrid System Configuration of a Large Scale Analog Emulator for Power System Analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1