Comparison of Fast and Slow Wave Correlation with Various Porosities between Two Measurement Technique

M. A. A. Wahab, R. Sudirman, M. A. A. Razak, F. Harun, Nurul Ashikin Abdul Kadir
{"title":"Comparison of Fast and Slow Wave Correlation with Various Porosities between Two Measurement Technique","authors":"M. A. A. Wahab, R. Sudirman, M. A. A. Razak, F. Harun, Nurul Ashikin Abdul Kadir","doi":"10.1109/SCORED.2019.8896305","DOIUrl":null,"url":null,"abstract":"With the discovery of fast and slow wave propagated through cancellous bone, the precision of the ultrasound measurement using through transmission technique to estimate bone quality getting better but limited to the certain part of the skeletal site. Thus, the pulse echo technique is proposed to solve the problem as the technique only uses one transducer to operate. The objective of this paper is to conduct an experiment for through transmission and pulse echo technique to investigate correlation fast and slow wave with various porosity of polyurethane foam. The recorded “incident” and “reflected” waves (mix wave) is then processed with the bandlimited deconvolution method in order to estimate the overlapping fast and slow wave. Further, the parameters for the mix, fast and slow waves for both incident and reflected wave are calculated, plotted against porosity and compared based on the correlation coefficient performance. The result shows that, the slope of attenuation of reflected and incident for both fast and slow waves shows a good correlation with porosity. The effect of scattering playing an important role for the total attenuation instead of absorption at high porosity, due to the acoustic properties of polyurethane foam is almost the same with water. Compared to mix wave, fast and slow wave is more correlated to the changes of porosity. Moreover, the reflected wave may suffer more effect of attenuation compared to the incident wave, thus, makes the correlation between wave parameter with porosity is lesser. Overall result indicates that, analyzed fast and slow wave instead of mix wave to estimate bone quality might improve the measurement accuracy.","PeriodicalId":231004,"journal":{"name":"2019 IEEE Student Conference on Research and Development (SCOReD)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Student Conference on Research and Development (SCOReD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCORED.2019.8896305","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

With the discovery of fast and slow wave propagated through cancellous bone, the precision of the ultrasound measurement using through transmission technique to estimate bone quality getting better but limited to the certain part of the skeletal site. Thus, the pulse echo technique is proposed to solve the problem as the technique only uses one transducer to operate. The objective of this paper is to conduct an experiment for through transmission and pulse echo technique to investigate correlation fast and slow wave with various porosity of polyurethane foam. The recorded “incident” and “reflected” waves (mix wave) is then processed with the bandlimited deconvolution method in order to estimate the overlapping fast and slow wave. Further, the parameters for the mix, fast and slow waves for both incident and reflected wave are calculated, plotted against porosity and compared based on the correlation coefficient performance. The result shows that, the slope of attenuation of reflected and incident for both fast and slow waves shows a good correlation with porosity. The effect of scattering playing an important role for the total attenuation instead of absorption at high porosity, due to the acoustic properties of polyurethane foam is almost the same with water. Compared to mix wave, fast and slow wave is more correlated to the changes of porosity. Moreover, the reflected wave may suffer more effect of attenuation compared to the incident wave, thus, makes the correlation between wave parameter with porosity is lesser. Overall result indicates that, analyzed fast and slow wave instead of mix wave to estimate bone quality might improve the measurement accuracy.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
两种测量技术在不同孔隙度下的快慢波相关性比较
随着快慢波在松质骨中传播的发现,通过透射技术测量骨质量的精度越来越高,但仅限于骨骼的特定部位。因此,提出了脉冲回波技术,以解决该技术仅使用一个换能器工作的问题。本文的目的是通过透射和脉冲回波技术的实验,研究快、慢波与聚氨酯泡沫不同孔隙率的相关性。记录的“入射”波和“反射”波(混合波)然后用带限反褶积方法进行处理,以估计重叠的快慢波。此外,计算了入射波和反射波的混合波、快波和慢波参数,并根据孔隙度绘制了相应的图,并根据相关系数性能进行了比较。结果表明,不论是快波还是慢波,反射波和入射波的衰减斜率都与孔隙度有很好的相关性。在高孔隙率下,由于聚氨酯泡沫的声学特性与水几乎相同,散射效应对总衰减起重要作用,而不是吸收效应。与混合波相比,快慢波与孔隙度的变化关系更密切。此外,反射波比入射波受衰减的影响更大,使得波参数与孔隙度的相关性较小。综合结果表明,用快慢波分析代替混合波估计骨质量可以提高测量精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Preliminary Implementation of the Next Generation Cannulation Simulator Multi-Input Power Converter for Renewable Energy Sources using Active Current Sharing Schemes Understanding the differences in students' attitudes towards social media use: A case study from Oman Effect Of Neurofeedback 2D and 3D Stimulus Content On Stress Mitigation Investigation of Segmented Rotor FEFSSM with Non-Overlap Windings in Various Slot-Pole Configurations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1