Design of distributed temperature and humidity monitoring system based on single-chip microcomputer

Yue Li, Longqing Shi, Peihe Zhai, Deming Zhang, Haibin Fan
{"title":"Design of distributed temperature and humidity monitoring system based on single-chip microcomputer","authors":"Yue Li, Longqing Shi, Peihe Zhai, Deming Zhang, Haibin Fan","doi":"10.1109/IMCEC51613.2021.9482261","DOIUrl":null,"url":null,"abstract":"With the continuous development of electronic technology, large-scale centralized control technology has also been greatly improved, the traditional RS485 bus technology, in the equipment network performance, a bus can be hooked up to 32 node equipment, to a large extent, to meet a number of warehouses or monitoring stations of the centralized control requirements. However, because the longest transmission distance of the RS485 bus can reach 1200 meters, even after the relay can not transmit a few kilometers distance, it is difficult to meet the requirements of more remote monitoring and control. At present, Ethernet communication has been widely used in life and production, Ethernet wiring is also very extensive, so the Ethernet communication mode instead of RS485 bus transmission mode is more conducive to the realization of a wide range of remote distributed network system. In this paper, for temperature and humidity monitoring system, with the characteristics of Ethernet without rewiring and convenient installation, a distributed temperature and humidity monitoring system based on Ethernet is developed, and the single chip computer is used to collect nodes, and the temperature and humidity monitoring system is completed by the design of the minimum system, the design of temperature and humidity collection circuit, A/D conversion circuit, Then through the RS485 bus will have a separate address of the unit temperature and humidity monitoring system connected to a bus, through a RS485 to TCP/IP protocol converter can realize single-chip Ethernet communication, greenhouse data transmission to the PC, remote monitoring function.","PeriodicalId":240400,"journal":{"name":"2021 IEEE 4th Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC)","volume":"48 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE 4th Advanced Information Management, Communicates, Electronic and Automation Control Conference (IMCEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMCEC51613.2021.9482261","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

With the continuous development of electronic technology, large-scale centralized control technology has also been greatly improved, the traditional RS485 bus technology, in the equipment network performance, a bus can be hooked up to 32 node equipment, to a large extent, to meet a number of warehouses or monitoring stations of the centralized control requirements. However, because the longest transmission distance of the RS485 bus can reach 1200 meters, even after the relay can not transmit a few kilometers distance, it is difficult to meet the requirements of more remote monitoring and control. At present, Ethernet communication has been widely used in life and production, Ethernet wiring is also very extensive, so the Ethernet communication mode instead of RS485 bus transmission mode is more conducive to the realization of a wide range of remote distributed network system. In this paper, for temperature and humidity monitoring system, with the characteristics of Ethernet without rewiring and convenient installation, a distributed temperature and humidity monitoring system based on Ethernet is developed, and the single chip computer is used to collect nodes, and the temperature and humidity monitoring system is completed by the design of the minimum system, the design of temperature and humidity collection circuit, A/D conversion circuit, Then through the RS485 bus will have a separate address of the unit temperature and humidity monitoring system connected to a bus, through a RS485 to TCP/IP protocol converter can realize single-chip Ethernet communication, greenhouse data transmission to the PC, remote monitoring function.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于单片机的分布式温湿度监测系统设计
随着电子技术的不断发展,大规模集中控制技术也得到了很大的提高,传统的RS485总线技术,在设备的网络性能上,一根总线可以接32个节点的设备,在很大程度上满足了多个仓库或监测站的集中控制要求。但是,由于RS485总线的最长传输距离可以达到1200米,即使经过继电器也无法传输几公里的距离,很难满足更加远程的监控要求。目前,以太网通信已经广泛应用于生活和生产中,以太网布线也非常广泛,因此以太网通信方式代替RS485总线传输方式更有利于实现大范围的远程分布式网络系统。本文针对温湿度监测系统,利用以太网无需重新布线、安装方便的特点,开发了一种基于以太网的分布式温湿度监测系统,采用单片机采集节点,通过最小系统的设计、温湿度采集电路的设计、a /D转换电路的设计、然后通过RS485总线将有单独地址的单元温湿度监控系统连接到总线上,通过RS485到TCP/IP协议转换器可以实现单片机以太网通信,将温室数据传输到PC机,实现远程监控功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The HT-TBD Algorithm for Large Maneuvering Targets with Fewer Beats and More Groups Key Technologies of Heterogeneous System General Data Service based on Virtual Table Research on Plant Disease Detection Technology Based on Wireless Sensor Network Leaf Segmentation Algorithm Based on Improved U-shaped Network under Complex Background Research on Anti-jamming Simulation based on Circular Array Antenna
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1