The Importance of Position of the Distal Fragment in Intertrochanteric Fracture of the Femur using Compression Hip Screw

J. Rha, H. Park, Young Bong Park, C. Lim, Seung Woo Kim
{"title":"The Importance of Position of the Distal Fragment in Intertrochanteric Fracture of the Femur using Compression Hip Screw","authors":"J. Rha, H. Park, Young Bong Park, C. Lim, Seung Woo Kim","doi":"10.12671/JKSF.2003.16.4.447","DOIUrl":null,"url":null,"abstract":"Purpose: We reviewed the amount of impaction and the change of neck shaft angle of intertrochanteric fracture of the femur which were treated with compression hip screw according to the fracture type and the displaced state of the distal fragment. Materials and Methods: There were 50 patients who had at least six months follow up, 13 men, and 37 women who were treated from January 1995 to December 2000. We have analysed the amount of impaction (measurement of the ratio between screw length and screw outside barrel length) and the change of neck shaft angle according to the fracture type and the displaced state of the distal fragment. The results were assessed statistically. Results: The fracture healing was achieved in about 13 weeks. There were 36 stable fracture types and 14 unstable fracture types by Evans classification. The most common osteoporotic singh index was grade II. The mean impaction amount of the fracture site was 5.4 mm and the mean neck shaft angle change was 1.5 ° of varus angulation. The mean tip apex distance was 32 mm. There was no case of lag screw penetration into the joint. There was significant difference in result according to the displaced state of the distal fragment. The amount of impaction was less in cases that anatomically reduced or got the posterolateralization of the distal Conclusion: The results of our study indicate that the anatomical reduction and posterolateralization of the distal fragment could reduce the amount of impaction and the change of neck shaft angle. We in reduce the failure.","PeriodicalId":298665,"journal":{"name":"Journal of the Korean Society of Fractures","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Korean Society of Fractures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12671/JKSF.2003.16.4.447","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: We reviewed the amount of impaction and the change of neck shaft angle of intertrochanteric fracture of the femur which were treated with compression hip screw according to the fracture type and the displaced state of the distal fragment. Materials and Methods: There were 50 patients who had at least six months follow up, 13 men, and 37 women who were treated from January 1995 to December 2000. We have analysed the amount of impaction (measurement of the ratio between screw length and screw outside barrel length) and the change of neck shaft angle according to the fracture type and the displaced state of the distal fragment. The results were assessed statistically. Results: The fracture healing was achieved in about 13 weeks. There were 36 stable fracture types and 14 unstable fracture types by Evans classification. The most common osteoporotic singh index was grade II. The mean impaction amount of the fracture site was 5.4 mm and the mean neck shaft angle change was 1.5 ° of varus angulation. The mean tip apex distance was 32 mm. There was no case of lag screw penetration into the joint. There was significant difference in result according to the displaced state of the distal fragment. The amount of impaction was less in cases that anatomically reduced or got the posterolateralization of the distal Conclusion: The results of our study indicate that the anatomical reduction and posterolateralization of the distal fragment could reduce the amount of impaction and the change of neck shaft angle. We in reduce the failure.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
加压髋螺钉治疗股骨粗隆间骨折时远端碎片位置的重要性
目的:根据股骨粗隆间骨折类型及远端碎片移位情况,回顾加压螺钉治疗股骨粗隆间骨折后的内嵌量及颈轴角的变化。材料与方法:1995年1月至2000年12月间,对50例患者进行了6个月以上的随访,其中男性13例,女性37例。根据骨折类型和远端碎片移位情况,分析了撞击量(测量螺钉长度与螺钉外筒长度之比)和颈轴角的变化。对结果进行统计学评估。结果:骨折愈合约13周。根据Evans分类,有36种稳定型骨折,14种不稳定型骨折。最常见的骨质疏松singh指数为II级。骨折部位的平均撞击量为5.4 mm,颈轴角的平均变化为1.5°内翻角。平均尖端距离为32 mm。没有拉力螺钉插入关节的情况。根据远端碎片移位状态的不同,结果有显著差异。结论:我们的研究结果表明,远端碎片解剖复位和后外侧化可以减少嵌塞量和颈轴角的变化。我们在减少失败。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis of Failures of Union of the Intertrochanteric Femoral Fractures Surgical Treatment of Internal Malleolar Fracture of the Ankle: Rush Rod Versus Plate Osteosynthesis Treatment of Infected Nonunion of Long Bone Shaft: Comparison between Fixation by Antibiotic-cement Loaded Intramedullary Nailing and Fixation by Antibiotic-cement Loaded External Monofixator Treatment of Completely Displaced Supracondylar Fracture of Humerus in Children. Arthroscopic-Assisted Reduction and Internal Fixation of Patella Fractures
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1