Passive Model-based Error Compensation For Beveled-tip Needle Deflection

Farid Tavakkolmoghaddam, Yang Wang, Charles Bales, Yiwei Jiang, C. Nycz, Zhanyue Zhao, G. Fischer
{"title":"Passive Model-based Error Compensation For Beveled-tip Needle Deflection","authors":"Farid Tavakkolmoghaddam, Yang Wang, Charles Bales, Yiwei Jiang, C. Nycz, Zhanyue Zhao, G. Fischer","doi":"10.1109/ISMR57123.2023.10130217","DOIUrl":null,"url":null,"abstract":"The interaction between the asymmetric (bevel) tip needle and the surrounding tissue results in the deflection of the needle and causes a significant targeting error in prostate biopsy. Several works have been proposed to mitigate this issue. While some have shown promising results, they require complex software and hardware which makes them difficult to deploy for clinical use. In this paper, we present a predictive model-based approach for passive compensation of the bevel tip needles in phantom tissues. We predict the needle deflection by approximating the initial deflection angle and simulating the needle path before insertion. The entry point is then modified based on the predicted deflection. To achieve this, we collected a set of needle insertion data into a gelatin phantom in an MRI study and used the data to find the parameters for the predictive model. The model was then tested in another MRI insertion study, which demonstrated promising results with an average of 75.2% targeting accuracy improvement compared with the uncompensated insertions.","PeriodicalId":276757,"journal":{"name":"2023 International Symposium on Medical Robotics (ISMR)","volume":"122 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 International Symposium on Medical Robotics (ISMR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISMR57123.2023.10130217","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The interaction between the asymmetric (bevel) tip needle and the surrounding tissue results in the deflection of the needle and causes a significant targeting error in prostate biopsy. Several works have been proposed to mitigate this issue. While some have shown promising results, they require complex software and hardware which makes them difficult to deploy for clinical use. In this paper, we present a predictive model-based approach for passive compensation of the bevel tip needles in phantom tissues. We predict the needle deflection by approximating the initial deflection angle and simulating the needle path before insertion. The entry point is then modified based on the predicted deflection. To achieve this, we collected a set of needle insertion data into a gelatin phantom in an MRI study and used the data to find the parameters for the predictive model. The model was then tested in another MRI insertion study, which demonstrated promising results with an average of 75.2% targeting accuracy improvement compared with the uncompensated insertions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于被动模型的斜尖针偏转误差补偿
不对称(斜角)针尖与周围组织之间的相互作用导致针的偏转,并导致前列腺活检中显著的靶向误差。已经提出了一些工作来缓解这个问题。虽然有些已经显示出有希望的结果,但它们需要复杂的软件和硬件,这使得它们难以部署到临床使用。在本文中,我们提出了一种基于预测模型的斜头针在幻体组织中的被动补偿方法。我们通过近似初始偏转角和模拟针在插入前的路径来预测针的偏转。然后根据预测的挠度修改入口点。为了实现这一目标,我们在MRI研究中收集了一组针插入明胶幻影的数据,并利用这些数据找到预测模型的参数。然后在另一项MRI插入研究中对该模型进行了测试,结果显示,与未补偿插入相比,该模型的瞄准精度平均提高了75.2%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of a Preliminary Use Case for Socially Assistive Robot-Augmented Early Intervention with Clinical Stakeholders Towards in-utero Navigational Assistance: A Multi Task Neural Network for Segmentation and Pose Estimation in Fetoscopy cHand: Open Source Hand Posture Visualization in CHAI3D Koopman Operator-based Extended Kalman Filter for Cosserat Rod Wrench Estimation Deep Kernel and Image Quality Estimators for Optimizing Robotic Ultrasound Controller using Bayesian Optimization
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1