Study on the Plutonium Holdup Measurement in Glove-Box

Yimei Cheng, Xiaoming Xu, Honghe Yin, Xinjun Li, Sijia Wang
{"title":"Study on the Plutonium Holdup Measurement in Glove-Box","authors":"Yimei Cheng, Xiaoming Xu, Honghe Yin, Xinjun Li, Sijia Wang","doi":"10.1115/icone29-90455","DOIUrl":null,"url":null,"abstract":"\n Based on passive total neutron counting with the 3He detectors, an assay system that can define the plutonium holdup in glove-box directly had been established through optimization design by Monte-Carlo simulation. The subsequent debugging for the electronics of this system ensured the system staying in a good operation state. The carried out experimental measurements had defined a series of parameters for the system, including the optimal operation voltage, detection efficiency for neutrons, spatial efficiency distribution, and the relationship between sample mass and the counts. Finally, according to the on-site measurements, the RSD of the measurement system for the glove-box holdup was 0.2%, which indicates the excellent stability of this system.","PeriodicalId":365848,"journal":{"name":"Volume 5: Nuclear Safety, Security, and Cyber Security","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 5: Nuclear Safety, Security, and Cyber Security","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/icone29-90455","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Based on passive total neutron counting with the 3He detectors, an assay system that can define the plutonium holdup in glove-box directly had been established through optimization design by Monte-Carlo simulation. The subsequent debugging for the electronics of this system ensured the system staying in a good operation state. The carried out experimental measurements had defined a series of parameters for the system, including the optimal operation voltage, detection efficiency for neutrons, spatial efficiency distribution, and the relationship between sample mass and the counts. Finally, according to the on-site measurements, the RSD of the measurement system for the glove-box holdup was 0.2%, which indicates the excellent stability of this system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
手套箱中钚含率测量方法的研究
基于3He探测器的被动全中子计数,通过蒙特卡罗模拟优化设计,建立了一个能直接确定手套箱中钚含率的分析系统。随后对系统的电子器件进行了调试,保证了系统处于良好的运行状态。实验测量确定了系统的一系列参数,包括最佳工作电压、中子探测效率、空间效率分布以及样品质量与计数的关系。最后,根据现场测量,手套箱含率测量系统的RSD为0.2%,表明该系统具有良好的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Margin Analysis of Conventional Island Under Beyond Design Basis External Flooding Scenario for NPP Multi-Units Nuclear Power Plant Site Initial Event Filtration Simulation Research on Safe Load-Reducing Operation Margin of Nuclear Power Unit With Clogging of the CFI Drum Net Research on Risk Characterization Method of Marine Biological Disaster Affecting Water Intake Safety of Nuclear Power Plant and Application of Design Protection A Drive-Through Passenger Vehicle Inspecting System Using X-Ray Digital Radiography
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1