Improvement of Engineering Methods for Calculating Ventilation and Air Conditioning of Museum Storage Facilities

S. Sargsyan, V. Borisova
{"title":"Improvement of Engineering Methods for Calculating Ventilation and Air Conditioning of Museum Storage Facilities","authors":"S. Sargsyan, V. Borisova","doi":"10.1109/FarEastCon50210.2020.9271633","DOIUrl":null,"url":null,"abstract":"The article is devoted to the problem of ventilation and air conditioning of the premises of the storage facilities of museums, the standards of which are mandatory. Due to the presence of a large number of paintings, documents, maps and drawings in the storages, the required air parameters are required for their safety and integrity. The equipment of ventilation and air conditioning systems in the premises of the museum storage facilities is dictated by the requirements of regulatory documents. At the same time, it is required to create high-quality air exchange. Supply and exhaust ventilation with forced circulation is considered optimal. The methodology for calculating the air exchange in the premises of museum storage facilities is presented, which allows to provide the required air parameters in a given volume. The article describes the storage facility as an object consisting of two control measurements: 1-wall volume; 2-internal volume. Schematic diagrams of the organization of air exchange in the premises of the storage facilities of museums according to the bottom-up scheme for the warm and cold periods of the year are given. The general schemes of heat and mass transfer processes in the ventilated volume of the premises of the museum storage facilities with two control volumes, which allow determining the air exchange for the normalized air parameters in a given volume, are presented. Diagram I-d shows the change in air parameters when organizing air exchange according to the scheme from bottom to top with air intake for recirculation of the upper zone of the near-wall volume during the warm period, and from the lower zone of the near-wall area during the cold season.","PeriodicalId":280181,"journal":{"name":"2020 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon)","volume":"219 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FarEastCon50210.2020.9271633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article is devoted to the problem of ventilation and air conditioning of the premises of the storage facilities of museums, the standards of which are mandatory. Due to the presence of a large number of paintings, documents, maps and drawings in the storages, the required air parameters are required for their safety and integrity. The equipment of ventilation and air conditioning systems in the premises of the museum storage facilities is dictated by the requirements of regulatory documents. At the same time, it is required to create high-quality air exchange. Supply and exhaust ventilation with forced circulation is considered optimal. The methodology for calculating the air exchange in the premises of museum storage facilities is presented, which allows to provide the required air parameters in a given volume. The article describes the storage facility as an object consisting of two control measurements: 1-wall volume; 2-internal volume. Schematic diagrams of the organization of air exchange in the premises of the storage facilities of museums according to the bottom-up scheme for the warm and cold periods of the year are given. The general schemes of heat and mass transfer processes in the ventilated volume of the premises of the museum storage facilities with two control volumes, which allow determining the air exchange for the normalized air parameters in a given volume, are presented. Diagram I-d shows the change in air parameters when organizing air exchange according to the scheme from bottom to top with air intake for recirculation of the upper zone of the near-wall volume during the warm period, and from the lower zone of the near-wall area during the cold season.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
博物馆仓储设施通风空调工程计算方法的改进
本文就博物馆仓储设施的通风空调问题进行了研究,这是一项强制性标准。由于存储库中存在大量的绘画,文件,地图和图纸,因此需要所需的空气参数以确保其安全性和完整性。博物馆仓储设施场所的通风和空调系统设备应符合规范性文件的要求。同时,要求创造高质量的空气交换。强制循环的供排气通风被认为是最佳的。介绍了计算博物馆存储设施场所内空气交换的方法,该方法允许在给定的体积内提供所需的空气参数。本文将存储设施描述为由两个控制测量组成的对象:1-壁体积;2-internal体积。根据自下而上的方案,给出了一年中暖季和寒季博物馆存储设施场所的空气交换组织示意图。介绍了博物馆存储设施通风室内的传热传质过程的一般方案,两个控制体允许在给定体积内确定归一化空气参数的空气交换。图I-d为从下往上组织换气方案时空气参数的变化情况,暖季从近壁容积上部进风,冷季从近壁容积下部进风再循环。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of Expediency of Using Wind Energy for Heat Supply on the Barents Sea Coast of Russia Method of Implementing a Fuzzy Logic Controller by Hardware Rational Design of Engineering Systems in High-Rise Buildings Optimizing Logical Structures of Decentralized Schedulers in Multicluster Systems and Computational Grids High-Performance Complex Event Processing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1