{"title":"Rugged telemetry system: testing results and design improvements","authors":"R. Weis, B. M. Beadle, B. L. Bachim","doi":"10.1117/12.323421","DOIUrl":null,"url":null,"abstract":"A rugged telemetry system for coiled-tubing drilling and other hostile environment applications is briefly described. System performance before and after being tested in drilling operations (rotating, drilling, and reaming) was unchanged. However, in a laboratory test at 150 degrees Celsius, signal- to-noise ratio performance at higher carrier frequencies was degraded. Design improvements are also presented.","PeriodicalId":293004,"journal":{"name":"Pacific Northwest Fiber Optic Sensor","volume":"46 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pacific Northwest Fiber Optic Sensor","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.323421","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A rugged telemetry system for coiled-tubing drilling and other hostile environment applications is briefly described. System performance before and after being tested in drilling operations (rotating, drilling, and reaming) was unchanged. However, in a laboratory test at 150 degrees Celsius, signal- to-noise ratio performance at higher carrier frequencies was degraded. Design improvements are also presented.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
坚固的遥测系统:测试结果和设计改进
简要介绍了一种用于连续油管钻井和其他恶劣环境应用的坚固型遥测系统。在钻井作业(旋转、钻井和扩眼)测试前后,系统性能没有变化。然而,在150摄氏度的实验室测试中,在较高载波频率下的信噪比性能下降。提出了设计改进方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fiber optic calorimeter Buried fiber intrusion detection sensor with minimal false alarm rates Integrated-optic sensors for high-voltage substation applications Fiber optic displacement sensor Fiber optic-based optical coherence tomography (OCT) for dental applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1