Telehealth Follow-up Using a Real-Time Electrocardiogram Device Improves Electrocardiogram Monitoring Duration and Patient Satisfaction After Catheter Ablation.

Circulation reports Pub Date : 2023-10-28 eCollection Date: 2023-11-10 DOI:10.1253/circrep.CR-23-0083
Mitsuru Takami, Koji Fukuzawa, Kunihiko Kiuchi, Hiroyuki Takahara, Kimitake Imamura, Toshihiro Nakamura, Yusuke Sonoda, Kazutaka Nakasone, Kyoko Yamamoto, Yuya Suzuki, Kenichi Tani, Hidehiro Iwai, Yusuke Nakanishi, Mitsuhiko Shoda, Atsushi Murakami, Shogo Yonehara, Ken-Ichi Hirata
{"title":"Telehealth Follow-up Using a Real-Time Electrocardiogram Device Improves Electrocardiogram Monitoring Duration and Patient Satisfaction After Catheter Ablation.","authors":"Mitsuru Takami, Koji Fukuzawa, Kunihiko Kiuchi, Hiroyuki Takahara, Kimitake Imamura, Toshihiro Nakamura, Yusuke Sonoda, Kazutaka Nakasone, Kyoko Yamamoto, Yuya Suzuki, Kenichi Tani, Hidehiro Iwai, Yusuke Nakanishi, Mitsuhiko Shoda, Atsushi Murakami, Shogo Yonehara, Ken-Ichi Hirata","doi":"10.1253/circrep.CR-23-0083","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> There is a strong demand for remote monitoring systems to gather health data. This study investigated the safety, usefulness, and patient satisfaction in outpatient care using telehealth with real-time electrocardiogram (ECG) monitoring after catheter ablation. <b><i>Methods and Results:</i></b> In all, 38 patients who underwent catheter ablation were followed up using telehealth. At the 3- and 6-month follow-up, a self-fitted Duranta ECG monitoring device was sent to the patient's home before the online consultation. Patients attached the devices themselves, and the doctors viewed the patients by video chat and performed real-time ECG monitoring. The frequency of hospital visits and the ECG monitoring duration were compared with conventional in-person follow-up data (n=102). The completion rate for telehealth follow-up was 32 of 38 patients (84%). The number of hospital visits during the 6 months was significantly lower with telehealth follow-up than with conventional follow-up (median [interquartile range] 1 [1-1] vs. 5 [3-5]; P<0.0001). However, the ECG monitoring duration was approximately 4-fold longer for the telehealth follow-up (median [interquartile range] 89 [64-117] vs. 24 [0.1-24] h; P<0.0001). No major adverse events were observed during the telehealth follow-up. Patient surveys showed high satisfaction with telehealth follow-up due to reduced hospital visits. <b><i>Conclusions:</i></b> A combination of telehealth follow-up with real-time ECG monitoring increased the ECG monitoring duration and patient satisfaction without any adverse events.</p>","PeriodicalId":94305,"journal":{"name":"Circulation reports","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10632073/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1253/circrep.CR-23-0083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/10 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: There is a strong demand for remote monitoring systems to gather health data. This study investigated the safety, usefulness, and patient satisfaction in outpatient care using telehealth with real-time electrocardiogram (ECG) monitoring after catheter ablation. Methods and Results: In all, 38 patients who underwent catheter ablation were followed up using telehealth. At the 3- and 6-month follow-up, a self-fitted Duranta ECG monitoring device was sent to the patient's home before the online consultation. Patients attached the devices themselves, and the doctors viewed the patients by video chat and performed real-time ECG monitoring. The frequency of hospital visits and the ECG monitoring duration were compared with conventional in-person follow-up data (n=102). The completion rate for telehealth follow-up was 32 of 38 patients (84%). The number of hospital visits during the 6 months was significantly lower with telehealth follow-up than with conventional follow-up (median [interquartile range] 1 [1-1] vs. 5 [3-5]; P<0.0001). However, the ECG monitoring duration was approximately 4-fold longer for the telehealth follow-up (median [interquartile range] 89 [64-117] vs. 24 [0.1-24] h; P<0.0001). No major adverse events were observed during the telehealth follow-up. Patient surveys showed high satisfaction with telehealth follow-up due to reduced hospital visits. Conclusions: A combination of telehealth follow-up with real-time ECG monitoring increased the ECG monitoring duration and patient satisfaction without any adverse events.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用实时心电图设备的远程健康随访提高了导管消融后心电图监测时间和患者满意度。
背景:对远程监测系统收集健康数据的需求很大。本研究探讨了导管消融后使用远程医疗和实时心电图监测的门诊护理的安全性、有效性和患者满意度。方法与结果:采用远程医疗对38例导管消融患者进行随访。在3个月和6个月的随访中,在在线咨询之前,将自行安装的Duranta心电图监护设备送到患者家中。患者自己连接设备,医生通过视频聊天查看患者并进行实时心电监测。将住院次数和心电监护时间与常规的面对面随访数据进行比较(n=102)。远程医疗随访完成率为32 / 38(84%)。6个月内,远程医疗随访的医院就诊次数显著低于常规随访(中位数[四分位数间距]1[1-1]对5 [3-5];结论:远程医疗随访与实时心电监护相结合,增加了心电监护时间和患者满意度,无不良事件发生。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Usefulness of Native T1 in Cardiac Magnetic Resonance Imaging and Echocardiographic Strain Parameters for Detecting Early Cardiac Involvement in Fabry Cardiomyopathy. Effect of Vericiguat on Left Ventricular Reverse Remodeling in Patients Who Have Heart Failure With Reduced Ejection Fraction - Special Focus on Patients Without Quadruple Medical Therapy. Efficacy of Inspiratory Muscle Training in Patients With Acute Decompensated Heart Failure. Real-World Evidence of Feasible Assessment and Intervention in Cardiovascular Physical Therapy for Older Patients With Heart Failure - Insight From the J-Proof HF of the Japanese Society of Cardiovascular Physical Therapy. Elevated B-Type Natriuretic Peptide Level as a Residual Risk Factor for Ventricular Arrhythmias Among Patients Undergoing Cardiac Resynchronization Therapy With Improved Left Ventricular Ejection Fraction.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1