Preoperative virtual reduction method for pelvic fractures based on statistical shape models and partial surface data

Wei Kou , Yaoyao He , Xiao Cheng , Zhewei Wang , Yuan Yang , Shaolong Kuang
{"title":"Preoperative virtual reduction method for pelvic fractures based on statistical shape models and partial surface data","authors":"Wei Kou ,&nbsp;Yaoyao He ,&nbsp;Xiao Cheng ,&nbsp;Zhewei Wang ,&nbsp;Yuan Yang ,&nbsp;Shaolong Kuang","doi":"10.1016/j.birob.2023.100130","DOIUrl":null,"url":null,"abstract":"<div><p>Virtual reduction is crucial for successful and accurate reduction of pelvic fractures. Various methods have been proposed in this regard. However, not all of them are applicable to every pelvic fracture. Among these methods, the efficiency and accuracy of the method based on statistical shape models in clinical applications require further improvement. This study proposes a virtual reduction method for pelvic fractures that uses statistical shape models and partial surface data of a broken pelvis. Simulated fracture and clinical case experiments were conducted to validate the accuracy and effectiveness of the proposed method. The simulated fracture experiments yielded an average error of 1.57 ± 0.39 mm and a maximum error of 12.82 ± 3.54 mm. The virtual reduction procedure takes approximately 40 s. Based on three clinical case experiments, the proposed method achieves an acceptable level of accuracy compared with manual reduction by a surgeon. The proposed method offers the advantages of shorter virtual reduction times and satisfactory reduction accuracy. In the future, it will be integrated into the preoperative planning system for pelvic fracture reduction, thereby improving patient outcomes.</p></div>","PeriodicalId":100184,"journal":{"name":"Biomimetic Intelligence and Robotics","volume":"3 4","pages":"Article 100130"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S266737972300044X/pdfft?md5=ed904a2f8c3ccdc8eab16a43963b8eff&pid=1-s2.0-S266737972300044X-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomimetic Intelligence and Robotics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S266737972300044X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Virtual reduction is crucial for successful and accurate reduction of pelvic fractures. Various methods have been proposed in this regard. However, not all of them are applicable to every pelvic fracture. Among these methods, the efficiency and accuracy of the method based on statistical shape models in clinical applications require further improvement. This study proposes a virtual reduction method for pelvic fractures that uses statistical shape models and partial surface data of a broken pelvis. Simulated fracture and clinical case experiments were conducted to validate the accuracy and effectiveness of the proposed method. The simulated fracture experiments yielded an average error of 1.57 ± 0.39 mm and a maximum error of 12.82 ± 3.54 mm. The virtual reduction procedure takes approximately 40 s. Based on three clinical case experiments, the proposed method achieves an acceptable level of accuracy compared with manual reduction by a surgeon. The proposed method offers the advantages of shorter virtual reduction times and satisfactory reduction accuracy. In the future, it will be integrated into the preoperative planning system for pelvic fracture reduction, thereby improving patient outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于统计形状模型和部分表面数据的骨盆骨折术前虚拟复位方法
虚拟复位是成功和准确复位骨盆骨折的关键。在这方面提出了各种方法。然而,并不是所有的方法都适用于每一种骨盆骨折。其中,基于统计形状模型的方法在临床应用中的效率和准确性有待进一步提高。本研究提出了骨盆骨折的虚拟复位方法,该方法使用骨盆骨折的统计形状模型和部分表面数据。通过模拟骨折和临床病例实验验证了该方法的准确性和有效性。模拟断裂实验的平均误差为1.57±0.39 mm,最大误差为12.82±3.54 mm。虚拟还原过程大约需要40秒。基于三个临床病例实验,与外科医生手动复位相比,该方法达到了可接受的精度水平。该方法具有虚拟约简时间短、约简精度高的优点。未来,它将被纳入骨盆骨折复位的术前计划系统,从而改善患者的预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
0.00%
发文量
0
期刊最新文献
An improved path planning and tracking control method for planetary exploration rovers with traversable tolerance Bathing assistive devices and robots for the elderly Human-in-the-loop transfer learning in collision avoidance of autonomous robots Forward solution algorithm of Fracture reduction robots based on Newton-Genetic algorithm SoftGrasp: Adaptive grasping for dexterous hand based on multimodal imitation learning
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1