Indoor PM2.5 concentrations in various retail stores in an urban city: Levels, sources and health risk assessment

IF 3.2 3区 工程技术 Q2 CONSTRUCTION & BUILDING TECHNOLOGY Indoor and Built Environment Pub Date : 2023-10-26 DOI:10.1177/1420326x231205792
Fatma Nur Eraslan, Özlem Özden Üzmez, Eftade O. Gaga
{"title":"Indoor PM<sub>2.5</sub> concentrations in various retail stores in an urban city: Levels, sources and health risk assessment","authors":"Fatma Nur Eraslan, Özlem Özden Üzmez, Eftade O. Gaga","doi":"10.1177/1420326x231205792","DOIUrl":null,"url":null,"abstract":"This study provides information about PM 2.5 indoor–outdoor mass concentrations, indoor/outdoor ratios (I/O) and health risks associated with PM 2.5 inhalation in seven various retail stores: photocopy centre, bakery, restaurant, hairdresser, dry cleaner, grocery store and hotel. Simultaneous indoor and outdoor measurements were performed in all retail stores in both summer and winter seasons, weekdays and weekends, and also during busy and less-active hours to obtain a realistic exposure assessment. According to the results, indoor PM 2.5 levels in the winter season were comparatively higher than those measured in the summer season. The highest PM 2.5 concentrations were measured at the hairdresser (3076.0 ± 1345.5 µg/m 3 ) and restaurant (2138.1 ± 636.4 µg/m 3 ) in each sampling period in winter. I/O ratios of &gt;1 were obtained at the hairdresser (7.3–72.3) and restaurant (1.6–17.3) in the winter season and at the hairdresser (1.3–12.7) and dry cleaner (1.1–1.7) in the summer season in all measurement periods. Quite high indoor PM 2.5 concentrations and consequently high I/O ratios indicated a strong contribution from indoor sources rather than infiltration of ambient air. Non-carcinogenic health risks due to PM 2.5 exposure were evaluated by estimating hazard quotient (HQ) values, and all HQ values were above the acceptable limit of 1 defined by US EPA for the photocopy centre, hairdresser and dry cleaner in both seasons. The results showed that indoor activities at the retail stores were significant for indoor PM 2.5 levels as well as occupational health risks faced by employees at retail stores.","PeriodicalId":13578,"journal":{"name":"Indoor and Built Environment","volume":"C-35 10","pages":"0"},"PeriodicalIF":3.2000,"publicationDate":"2023-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor and Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1420326x231205792","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study provides information about PM 2.5 indoor–outdoor mass concentrations, indoor/outdoor ratios (I/O) and health risks associated with PM 2.5 inhalation in seven various retail stores: photocopy centre, bakery, restaurant, hairdresser, dry cleaner, grocery store and hotel. Simultaneous indoor and outdoor measurements were performed in all retail stores in both summer and winter seasons, weekdays and weekends, and also during busy and less-active hours to obtain a realistic exposure assessment. According to the results, indoor PM 2.5 levels in the winter season were comparatively higher than those measured in the summer season. The highest PM 2.5 concentrations were measured at the hairdresser (3076.0 ± 1345.5 µg/m 3 ) and restaurant (2138.1 ± 636.4 µg/m 3 ) in each sampling period in winter. I/O ratios of >1 were obtained at the hairdresser (7.3–72.3) and restaurant (1.6–17.3) in the winter season and at the hairdresser (1.3–12.7) and dry cleaner (1.1–1.7) in the summer season in all measurement periods. Quite high indoor PM 2.5 concentrations and consequently high I/O ratios indicated a strong contribution from indoor sources rather than infiltration of ambient air. Non-carcinogenic health risks due to PM 2.5 exposure were evaluated by estimating hazard quotient (HQ) values, and all HQ values were above the acceptable limit of 1 defined by US EPA for the photocopy centre, hairdresser and dry cleaner in both seasons. The results showed that indoor activities at the retail stores were significant for indoor PM 2.5 levels as well as occupational health risks faced by employees at retail stores.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
城市各类零售商店室内PM2.5浓度:水平、来源及健康风险评估
本研究提供了7家不同零售商店(影印中心、面包店、餐馆、理发店、干洗店、杂货店和酒店)中pm2.5室内外质量浓度、室内外比(I/O)以及与吸入pm2.5相关的健康风险的信息。在夏季和冬季,工作日和周末,以及繁忙和不太活跃的时间,在所有零售商店同时进行室内和室外测量,以获得真实的暴露评估。结果表明,冬季室内pm2.5浓度高于夏季。在冬季每个采样期内,理发店和餐厅的PM 2.5浓度最高,分别为3076.0±1345.5µg/m 3和2138.1±636.4µg/m 3。在所有测量期内,冬季美发店(7.3-72.3)和餐厅(1.6-17.3)的I/O比为1,夏季美发店(1.3-12.7)和干洗店(1.1-1.7)的I/O比为1。相当高的室内PM 2.5浓度和由此产生的高I/O比率表明,室内污染源的贡献很大,而不是环境空气的渗透。通过估算危害商(HQ)值来评估PM 2.5暴露造成的非致癌性健康风险,所有HQ值均高于美国环保署为两个季节的影印中心、发廊和干洗店规定的可接受限值1。结果表明,零售商店的室内活动对室内PM 2.5水平和零售商店员工面临的职业健康风险具有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indoor and Built Environment
Indoor and Built Environment 环境科学-工程:环境
CiteScore
6.40
自引率
25.00%
发文量
130
审稿时长
2.6 months
期刊介绍: Indoor and Built Environment publishes reports on any topic pertaining to the quality of the indoor and built environment, and how these might effect the health, performance, efficiency and comfort of persons living or working there. Topics range from urban infrastructure, design of buildings, and materials used to laboratory studies including building airflow simulations and health effects. This journal is a member of the Committee on Publication Ethics (COPE).
期刊最新文献
Dynamics of indoor volatile organic compounds and seasonal ventilation strategies for residential buildings in Northeast China The indoor thermal environment performance of various air-conditioning system configurations and airflow modes in a large space museum building Leakage identification and correlation coefficient method for industrial workshop production process combining with computational fluid dynamics Synthesis and performance study of biomass-based suppressant and its application in radioactive aerosol sedimentation Modelling of radiation and flow fields in in-duct ultraviolet germicidal irradiation systems with and without ribs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1