{"title":"A wintertime thermal analysis of New Zealand Homestar certified apartments for older people","authors":"Rochelle Ade, Michael Rehm, Priya Vishnupriya","doi":"10.1080/09613218.2023.2256434","DOIUrl":null,"url":null,"abstract":"The New Zealand Building Code mandates maintaining habitable spaces and bathrooms in elderly homes at a minimum internal temperature of 16°C with adequate ventilation. This study assesses the thermal wintertime performance of 40 subsidized apartments designed for older residents within a 7-Homestar certified building in Auckland. The building performs well, falling below the 16°C threshold only 5 per cent of the time across all units. However, inconsistencies exist, particularly on the top floor (Level 3), which is colder than other levels. This reveals a potential flaw in the typology approach of green certifications, like Homestar, where certifying a single dwelling within an apartment building does not guarantee uniform thermal performance across all units.","PeriodicalId":55316,"journal":{"name":"Building Research and Information","volume":"32 1","pages":"0"},"PeriodicalIF":3.7000,"publicationDate":"2023-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Building Research and Information","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/09613218.2023.2256434","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The New Zealand Building Code mandates maintaining habitable spaces and bathrooms in elderly homes at a minimum internal temperature of 16°C with adequate ventilation. This study assesses the thermal wintertime performance of 40 subsidized apartments designed for older residents within a 7-Homestar certified building in Auckland. The building performs well, falling below the 16°C threshold only 5 per cent of the time across all units. However, inconsistencies exist, particularly on the top floor (Level 3), which is colder than other levels. This reveals a potential flaw in the typology approach of green certifications, like Homestar, where certifying a single dwelling within an apartment building does not guarantee uniform thermal performance across all units.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新西兰民宿认证的老年人公寓冬季热分析
《新西兰建筑规范》规定,养老院的可居住空间和浴室内部温度应保持在16°C以下,并保持足够的通风。本研究评估了奥克兰7-Homestar认证建筑内40套为老年居民设计的补贴公寓的冬季热性能。该建筑表现良好,在所有单元中只有5%的时间低于16°C的阈值。然而,不一致是存在的,特别是在顶楼(第3层),它比其他楼层更冷。这揭示了绿色认证的类型学方法的潜在缺陷,如Homestar,在该方法中,对公寓楼内的单个住宅进行认证并不能保证所有单元的均匀热性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Building Research and Information
Building Research and Information 工程技术-结构与建筑技术
CiteScore
8.60
自引率
7.70%
发文量
43
审稿时长
>12 weeks
期刊介绍: BUILDING RESEARCH & INFORMATION (BRI) is a leading international refereed journal focussed on buildings and their supporting systems. Unique to BRI is a focus on a holistic, transdisciplinary approach to buildings and the complexity of issues involving the built environment with other systems over the course of their life: planning, briefing, design, construction, occupation and use, property exchange and evaluation, maintenance, alteration and end of life. Published articles provide conceptual and evidence-based approaches which reflect the complexity and linkages between cultural, environmental, economic, social, organisational, quality of life, health, well-being, design and engineering of the built environment.
期刊最新文献
Exploring the feasibility of mobile robots for post-occupancy evaluations Indoor environmental evaluation of traditional Chinese medicine clinic – taking the treatment space as an example Towards circular renovation: a comparative review of circular economy integration in sustainable building rating systems Perceptions of volume home builders and the transition to net zero emissions housing in Australia The impact of light adjustment versus tuneable white mode on ICU staff’s circadian rhythms
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1