Feel, move, or walk? Which has a greater contribution to functioning in total knee arthroplasty? A comparative study between two instrumentations based on a classification and regression tree
Ana Paula Fontes, Rui Miguel Cintra, Luís Filipe Gomes, João Paulo Sousa
{"title":"Feel, move, or walk? Which has a greater contribution to functioning in total knee arthroplasty? A comparative study between two instrumentations based on a classification and regression tree","authors":"Ana Paula Fontes, Rui Miguel Cintra, Luís Filipe Gomes, João Paulo Sousa","doi":"10.1097/bco.0000000000001245","DOIUrl":null,"url":null,"abstract":"Background: This study aimed to know which variables most contribute to the functioning acquired in the third month using the Western Ontario and McMaster Universities Arthritis Index (WOMAC) and a multivariate analysis through classification and regression tree (CRT), comparing the conventional instrumentation (CI), and patient-specific instrumentation (PSI). Methods: This is an observational and retrospective study. The sample consisted of 252 patients, 68 receiving CI (27.0%) and 184 receiving PSI (73.0%). The functional variables of the study were: knee pain, passive flexion and extension, gait distance and the domains of the WOMAC index. Results: The CRT method identified that the only explanatory variable that contributed to the highest functioning in the CI group (13.2 in the WOMAC) was pain in the third month with a value ≤2.5 in the visual analog scale (VAS). In the PSI group, the variable that best explained functioning was pain in the first postoperative month (VAS ≤4.5), with the best functional result (2.8 in WOMAC) referring to the patients who walked >320.5 m in the 6-minute walk test in the first month and who had flexion of >112.5 in the third month. Conclusions: Feeling pain is the variable with the most significant explanatory power for the results achieved in functioning at the third month, regardless of the arthroplasty instrumentation employed. Moving the knee in higher flexion ranges and obtaining higher mean values of gait speed also positively influences functioning in patients subjected to PSI.","PeriodicalId":10732,"journal":{"name":"Current Orthopaedic Practice","volume":"53 38","pages":"0"},"PeriodicalIF":0.2000,"publicationDate":"2023-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Orthopaedic Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/bco.0000000000001245","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study aimed to know which variables most contribute to the functioning acquired in the third month using the Western Ontario and McMaster Universities Arthritis Index (WOMAC) and a multivariate analysis through classification and regression tree (CRT), comparing the conventional instrumentation (CI), and patient-specific instrumentation (PSI). Methods: This is an observational and retrospective study. The sample consisted of 252 patients, 68 receiving CI (27.0%) and 184 receiving PSI (73.0%). The functional variables of the study were: knee pain, passive flexion and extension, gait distance and the domains of the WOMAC index. Results: The CRT method identified that the only explanatory variable that contributed to the highest functioning in the CI group (13.2 in the WOMAC) was pain in the third month with a value ≤2.5 in the visual analog scale (VAS). In the PSI group, the variable that best explained functioning was pain in the first postoperative month (VAS ≤4.5), with the best functional result (2.8 in WOMAC) referring to the patients who walked >320.5 m in the 6-minute walk test in the first month and who had flexion of >112.5 in the third month. Conclusions: Feeling pain is the variable with the most significant explanatory power for the results achieved in functioning at the third month, regardless of the arthroplasty instrumentation employed. Moving the knee in higher flexion ranges and obtaining higher mean values of gait speed also positively influences functioning in patients subjected to PSI.
期刊介绍:
Lippincott Williams & Wilkins is a leading international publisher of professional health information for physicians, nurses, specialized clinicians and students. For a complete listing of titles currently published by Lippincott Williams & Wilkins and detailed information about print, online, and other offerings, please visit the LWW Online Store. Current Orthopaedic Practice is a peer-reviewed, general orthopaedic journal that translates clinical research into best practices for diagnosing, treating, and managing musculoskeletal disorders. The journal publishes original articles in the form of clinical research, invited special focus reviews and general reviews, as well as original articles on innovations in practice, case reports, point/counterpoint, and diagnostic imaging.